I.Basic definition of Schneider SM6 semi insulated ring main unit product

Schneider SM6, also known as semi insulated ring main unit, is characterized by the core switch being sealed in SF6 gas, while busbars, cables, etc. are exposed to air, hence it is called semi insulated.And for fully insulated ring main units such as SafeRing and 8DJH, all live conductors are sealed inside the box. During the operation of the product, personnel cannot come into contact with the live conductors, which further ensures the safety of operators and maintenance personnel. So technically speaking, full insulation is more advanced, and currently semi insulated ring main unit products are no longer used in China.

Schneider-SM6-switchgear-internal-structure-operation-view

Schneider SM6 switchgear internal structure operation view


Schneider launched the SM6 series modular ring main unit products as early as 1991. Initially, this Schneider SM6 only supported the highest SM6 24kV voltage level, commonly known as the SM6 24 Schneider in the industry. One product covered all voltage levels below 24kV. By 2010, there were already one million Sm6-24 Schneider units in operation.
But later on, it also expanded to 36kV products and launched the SM6 36 Schneider series, alongside 24kV products. If you need to obtain equipment operation and maintenance instructions, you can refer to the official Schneider SM6 manual for complete installation, debugging, and maintenance instructions.

II.Schneider SM6 full series official product model list

1. Load switch and fuse combination unit

  • IM/IMC/IMB: Load switch unit (standard/compact/expandable)
  • PM: Fused switch unit
  • QM/QMC/QMB: Fuse load switch combination protection unit (commonly used for distribution transformer protection)
  • SM: Isolation switch unit

2. Circuit breaker and contactor unit

  • DM1-A/DM1-D/DM1-S: Single isolated fixed SF ₆ circuit breaker unit
  • DMV-A/DMV-D/DMV-S: Single Isolation Fixed Vacuum Circuit Breaker Unit (Front Operation)
  • DMVL-A: Single Isolation Fixed Vacuum Circuit Breaker Unit (Side Operation)
  • DM1-W/DM1-Z: withdrawable single isolation SF ₆ circuit breaker unit
  • DM2: Dual Isolation SF ₆ Circuit Breaker Unit
  • CRM/CVM: Combination Unit of High Voltage Contactors and Contactors with Fuses

3. Metering&Sensing Unit

  • CM/CM2: Voltage Transformer (PT) Unit
  • GBC-A/GBC-B: Current (CT) and/or Voltage Measurement Unit

4. Busbar&Incomer Units

  • NSM cables: Dual power main and backup incoming cable units
  • NSM busbars: Main incoming busbar and backup cable incoming unit
  • GAM/GAM2: Incoming cable terminal connection unit
  • GIM: Intermediate Bus Transition Unit
  • GEM/GBM: Bus Expansion and Switching Connection Unit

5. Auxiliary transformer and safety grounding unit 

  • TM: Auxiliary Unit for Medium/Low Voltage Transformers
  • EMB: Busbar specific grounding switch unit
  • Custom Modules: Non standard special functional units (supporting customization and deepening according to a single image)

III.Detailed explanation of Schneider SM6 core functional unit structure

IM load switch unit/fuse switch combination unit

  • Switchgear: Isolation switches and grounding switches are installed in a sealed enclosure filled with SF ₆ gas to meet the requirements of a "sealed pressure system", which is also the core structural feature of Schneider SM6 switchgear.
  • Busbars system: All busbars are located on the same horizontal plane, making it easy to expand switchgear or connect with existing equipment in the future.

  • Connection: By wiring from the front, it can be connected to the lower isolation switch and grounding switch terminal (IM cabinet) or the lower fuse terminal (PM and QM cabinet). This compartment also has a grounding switch located downstream of the medium voltage fuse to protect the unit.
  • Operating mechanism: It includes the mechanical components for operating isolation switches and grounding switches, and provides corresponding operating instructions (positive break). The operating details can refer to the guidelines in Schneider SM6 manual to avoid misoperation.
  • Low voltage section: Install terminal blocks (if equipped with electric operation options), low-voltage fuses, and compact relay devices. If more space is needed, an additional shell can be added to the top of the cabinet.

SF ₆ type circuit breaker unit

The circuit breaker unit design of this Schneider Electric SM6 switchgear ensures operational stability:

  • Switchgear: Isolation switches and grounding switches are installed in enclosed enclosures filled with SF ₆ gas, meeting the requirements of a "sealed pressure system".
  • Busbars system: All busbars are located on the same horizontal plane, which facilitates the subsequent expansion of switchgear and connection with existing equipment. The busbar design of Sm6 24kV and Sm6 36 Schneider is unified and compatible with the expansion of units in the same series.
  • Connection and switchgear: can be accessed from the front and connected to the downstream terminal of the circuit breaker.

‌IV‌.Schneider SM6 Full Voltage Level Official Technical Parameter Table

The entire series of Schneider SM6 switchgear covers four core voltage levels, among which the core parameters of the largest market stock Sm6 24kV series and SM6 36 Schneider series are as follows:

Technical Parameter 12 kV Class 17.5 kV Class 24 kV Class (SM6-24) 36 kV Class (SM6-36)
Rated Voltage 12 kV 17.5 kV 24 kV 36 kV
Power Frequency Withstand Voltage (1 min) 28 kV 38 kV 50 kV 70 kV
Power Frequency Withstand Voltage (across isolating gap) 32 kV 45 kV 60 kV 80 kV
Lightning Impulse Withstand Voltage (1.2/50µs) 75 kV 95 kV 125 kV 170 kV
Lightning Impulse Withstand Voltage (across isolating gap) 85 kV 110 kV 145 kV 195 kV
Rated Continuous Current (In) 400 / 630 / 1250 A 400 / 630 / 1250 A 400 / 630 / 1250 A 630 / 1250 A
Short-time Withstand Current  12.5 / 16 / 20 / 25 kA 12.5 / 16 / 20 / 25 kA 12.5 / 16 / 20 / 25 kA 12.5 / 25 kA
Circuit Breaker Short-circuit Breaking Capacity (Isc) 20 / 25 kA 20 / 25 kA 20 / 25 kA 20 kA

Friendly Reminder:Available ratings and options depend on configuration. Contact us to confirm specifications for your project.

 

Summary of Schneider SM6 Overseas Market Application Status

Schneider Electric SM6 is a very classic ring main unit product, commonly known in the industry as schneider electric sm6 switchgear / schneider sm6 switchgear, Until today, Indonesian PLN still insists on bidding for this type of ring main unit product, with the mainstream procurement model focused on the SM6 24 Schneider (Sm6 24kv), and there is also a stable demand for the SM6 36 Schneider.

Key Features

  • Sealed-for-life SF₆ gas tank for maintenance-free operation
  • Extensible on both sides for future feeder expansion
  • Motorization-ready for smart grid automation
  • Compact modular footprint for kiosk and indoor installation

Documentation

Catalogs, CAD drawings and manuals are free — leave your work email and we send the package within 12 hours.

Application Scenarios

Where SM6 delivers — typical on-site installations across industries and regions.

Schneider SM6 24kV MV switchgear industrial project installation

01

Schneider SM6 24kV MV switchgear industrial project installation

Schneider SM6 MV switchgear for data center infrastructure

02

Schneider SM6 MV switchgear for data center infrastructure

Schneider SM6 switchgear finished product factory delivery

03

Schneider SM6 switchgear finished product factory delivery