Medium Voltage Switchgear

Schneider PremSeT MV Switchgear | 17.5kV SF6-Free

Compact, modular MV switchgear with a reduced footprint — designed for space-constrained substations, wind farms and solar plants.

WhatsApp

Product Overview

PremSeT is Schneider Electric's SF6-free MV switchgear for sale, built on the Shielded Solid Insulation System (SSIS) — all live parts are encapsulated, shielded and grounded, with an air-based vacuum circuit breaker for switching. For buyers comparing price and evaluating suppliers, PremSeT is designed for utilities, industrial plants, data centers and commercial buildings that need a compact, low-risk MV solution in primary or secondary distribution up to 17.5 kV.

Instead of gas insulation, PremSeT seals every live conductor in ground-shielded solid insulation, so there is no SF6, no gas handling and no leakage monitoring — for buyers this means: eliminated internal-arc risk from exposed busbars, 10-year maintenance intervals instead of yearly checks, and reduced total cost of ownership — all in a footprint roughly half that of conventional air-insulated switchgear, while keeping familiar breaker operation and IEEE C37.20.3 / UL Listed compliance.

As utilities and specifiers move away from SF6 toward sustainable MV portfolios, SF6-free technology is becoming a baseline requirement rather than an option. PremSeT delivers that transition today without sacrificing reliability or redesigning your switchgear room.

Internal structure diagram

 Why Choose Schneider Electric PremSeT?

1. Shielded Solid Insulation (2SIS)

Earthed shielding protects live parts from dust, moisture, and contamination, improving insulation reliability.

2. SF6-Free Vacuum Switching

Vacuum interrupters provide reliable arc extinction without SF6 gas handling or maintenance.

3. 3-in-1 Switching Technology

Integrates switching, isolation, and earthing functions with mechanical interlocks for safer operation.

 4. Compact Modular Design

Modular construction reduces installation space and simplifies system expansion.

5. Low Maintenance

Sealed solid insulation and vacuum switching reduce routine maintenance requirements.

 6. Smart Protection & Monitoring

Supports protection relays, fault detection, electrical measurements, and remote monitoring.

Real-world Case Studies

Technical Specifications

Technical Parameter Specification
Rated Voltage 12 kV
Rated Busbar Current 630 A / 1250 A
Rated Short-Time Withstand Current 25 kA / 31.5 kA
Power-Frequency Withstand Voltage 42 / 48 kV, 1 min
Lightning Impulse Withstand Voltage (BIL) 95 / 110 kV
Cable Earthing Switch 25 kA, M1, E2
Degree of Protection IP4X
Overall Dimensions (W × H × D) 375 × 1550 × 910 mm
Insulation Technology Shielded Solid Insulation; All Live Components Encapsulated, Shielded and Earthed
Switching Technology Vacuum Circuit Breaker or Vacuum Load Break Switch
Applicable Standards IEC, GB, DL

Real-World Application Cases

PremSeT is deployed across utility, industrial and commercial networks worldwide where safety and continuity matter most. In urban underground distribution, its Shielded Solid Insulation System lets utilities install compact, maintenance-light switchgear in flooded-prone vaults and tight substations — no SF6, no gas handling, no leakage monitoring. For data centers and hospitals, the 10-year maintenance interval and reduced internal-arc risk keep critical loads protected with fewer outages. In renewable and industrial plants, air-based vacuum interruption supports frequent switching operations reliably, while the compact footprint fits into retrofit spaces without expanding the switchgear room. From feeder automation to heavy-duty line protection, PremSeT delivers SF6-free reliability in real operating environments.

System Upgrade

On-site demonstration

An on-site demonstration verifies insulation reliability, operating mechanism, and bay compatibility. PremSeT's Shielded Solid Insulation (SSIS) grounds and encapsulates every live conductor — no SF6 pressure check, no gas refill or recovery; confirm shielding is intact with no surface discharge. Breaker sequence: open, move to isolated (visible break), close earthing switch, verify via observation window. Check installation dimensions and cable entries against existing civil works. At 17.5 kV, the vacuum interrupter contains the arc. Bring the single-line diagram to review secondary wiring and local/remote operation.

Event Setup

Why Buy from Funator

  •  In stock now — PremSeT held in our warehouse, not on a 40-week OEM lead time; we confirm availability before quoting.

  • Serial verification — nameplate and serial sent before payment, so you can confirm authenticity with Schneider directly.

  • FAT before dispatch — factory acceptance testing on vacuum breaker, three-position mechanism, insulation and secondary wiring, with full test records.

  • Global logistics — export packing, customs documentation, insured delivery to 50+ countries; cable-entry orientation confirmed against your site.

  • Engineering support — sizing, single-line review and drawings within 24 hours, so the unit matches your existing bay with no rework.

FAQ

1. Is this PremSeT brand-new or refurbished?
Brand-new Schneider original with a full serial number. Before payment we send the nameplate and serial so you can verify authenticity with Schneider directly, eliminating refurbished or grey-market risk.

2. What does the price include?
Price covers the unit, factory acceptance testing, export packing and standard accessories; freight and duties are excluded. FOB and CIF are quoted separately, itemized by breaker, CTs, secondary scheme and configuration so you can audit each line.

3. What is the lead time?
Standard models are in stock and ship once configuration is confirmed; special voltage/current ratings are manufactured to order, typically 4–8 weeks. Lead time is fixed in the quotation and not changed by exchange-rate movement.

4. What documentation do you provide?
We supply factory test reports (vacuum breaker, three-position mechanism, insulation and secondary-circuit records), nameplate data, single-line diagram, outline drawings and export customs documentation. Original certificates or third-party inspection are available on request.

5. Can you customize it to my bay?
Yes — cable entry/exit direction, CT ratios, secondary protection schemes and interlocking logic can be tailored. Send your single-line diagram and protection setting list; we issue confirmation drawings within 24 hours to match your existing civil works and bay.

6. Do you support installation and commissioning?
Remote guidance is standard, with on-site engineers available if needed. The unit arrives ready to install — the vacuum breaker is factory-set — so on site you only verify earthing, secondary wiring and local/remote switching.

Key Features

  • Internal arc classified (IAC) for operator safety
  • LSC2B service continuity — no outage for maintenance
  • Easergy smart-sensor ready for condition monitoring
  • Front-access cable compartment, compact footprint

Documentation

Catalogs, CAD drawings and manuals are free — leave your work email and we send the package within 12 hours.

Application Scenarios

Where PremSeT delivers — typical on-site installations across industries and regions.

industies

01

industies

Data Center

02

Data Center

Infrastructure

03

Infrastructure