Low Voltage Switchgear

Schneider Okken LV Switchboard | Power Distribution & Motor Control

Premium LV switchboard up to 7300 A / 150 kA for data centers, oil & gas and heavy industry — designed for maximum availability.

WhatsApp

Product Overview

Okken sits at the top of the Schneider LV range — 7300 A, 150 kA, withdrawable functional units and some of the highest availability figures published for a low-voltage switchboard. It is the standard for oil & gas, heavy industry and Tier-rated data centers.

Funator supplies Okken lineups configured to your single-line diagram, with factory witness testing available on request. Stock positions cover common feeder and incomer units for fast-track projects.

Inspection Site

 

Key Features

1. High-quality material selection and rigorous manufacturing standards ensure reliable electrical and mechanical performance.
2. Meets requirements for nuclear-safety-grade electrical equipment; capable of withstanding a 9.6-magnitude earthquake.
3. Features industry-leading short-circuit withstand capacity and the highest level of internal arc withstand capability, ensuring stability and safety.
4. Patented dual-clamp design prevents wear on power distribution busbars; allows for circuit upgrades or modifications without power interruption, ensuring continuous power supply.
5. Supports mixed configurations of MCC/PCC and incoming/outgoing feeder units; offers 7 types of functional units, 9 drawer sizes, and both withdrawable and fixed-type options to provide versatile solutions.
6. Patented "fish-shaped" busbar design, removable cross-beams, and pre-fabricated transport bases make installation and maintenance simple and efficient.
7. IP54 ingress protection rating; holds various maritime certifications and complies with Shell’s DEP standards, offering exceptional environmental resilience.

Technical Specifications

Parameter Specification
Rated Operational Voltage (Ue) 690 V AC
Rated Insulation Voltage (Ui) 1000 V
Rated Frequency 50/60 Hz
Rated Impulse Withstand Voltage (Uimp) 12 kV
Overvoltage Category / Pollution Degree IV / 3
Horizontal Main Busbar Rated Current Up to 7300 A
Horizontal Main Busbar Short-Time Withstand Current (Icw) Up to 150 kA / 1 s
Horizontal Main Busbar Peak Withstand Current (Ipk) Up to 330 kA
Vertical Distribution Busbar Rated Current 4000 / 2100 / 2000 A, depending on configuration
Vertical Distribution Busbar Short-Time Withstand Current (Icw) Up to 100 kA / 1 s
Vertical Distribution Busbar Peak Withstand Current (Ipk) Up to 220 kA
Internal Arc Withstand 100 kA / 0.3–0.5 s, depending on tested configuration

Ratings depend on the selected configuration and operating conditions. Refer to the applicable technical documentation and test reports for the supplied assembly.

Installation and  safety

Okken switchboard solutions are designed andcustom built to maximize the safety of personnel.Their best-in-class level of protection enables peaceof mind during installation and in everyday operations.

Production Site

Reliability and Service Continuity

Okken uses Schneider Electric components and accessories manufactured to controlled quality standards. Compatibility between the switchboard, functional units and installed devices is tested and validated, covering electrical interfaces, mechanical fit and electromagnetic compatibility (EMC).

For replacement or expansion, use components approved for the selected Okken configuration. Check electrical ratings, mounting interfaces and connections against the validated design to maintain system compatibility.

Inspection Site

Certificate

CertificateFAQ

1. What is Schneider Okken used for?
Okken is designed for low-voltage power distribution and motor control in industrial plants, data centers and infrastructure.

2. What voltage and current ratings are available?
Okken supports up to 690 V AC and main busbar ratings up to 7300 A, depending on configuration.

3. Does Okken support withdrawable units?
Yes. Withdrawable functional units are available to simplify replacement and maintenance.

4. Can Okken be expanded later?
Its modular design supports expansion, subject to available space, busbar capacity and the original configuration.

5. What protection options are available?
Options include protection up to IP54 and internal separation up to Form 4b, depending on the assembly.

6. What information is needed for a quotation?
Provide your single-line diagram, voltage, current, fault level, protection requirements and installation conditions.

Key Features

  • Fully type-tested to IEC 61439-1/-2
  • Form 4b separation for maximum safety
  • Arc-proof design with zone isolation
  • Front and rear access configurations

Documentation

Catalogs, CAD drawings and manuals are free — leave your work email and we send the package within 12 hours.

Application Scenarios

Where Okken delivers — typical on-site installations across industries and regions.

industies

01

industies

Data Center

02

Data Center

Infrastructure

03

Infrastructure