01
Low Voltage Switchgear
Authorized Schneider BlokSeT Da fixed ATS switchgear for dual-source power backup. IEC 61439-2 & Form 4b compliant for data centers & industry. Get RFQ.
In Stock The Blokset Da model is a dedicated dual-power-source transfer switch cabinet within Schneider Electric’s Blokset low-voltage switchgear system. Manufactured by Schneider-authorized switchgear manufacturers according to standard processes, it is specifically designed for stationary low-voltage power distribution systems to reliably switch between two independent power sources (main utility power + backup generator), ensuring uninterrupted power supply to critical loads.
This cabinet model shares a completely uniform cabinet frame, busbar interfaces, and installation dimensions with the Blokset D-type feeder cabinet. It can be directly connected in parallel with standard feeder cabinets, ensuring a consistent appearance for the entire substation, interchangeable spare parts, and standardized operation and maintenance procedures—all without the need for additional transition cabinets.
The cabinet features a fixed compartmentalized structure, internally divided into four independent compartments: busbar compartment, switchgear compartment, cable compartment, and instrumentation compartment. It supports up to Type 4, Class 2 compartmentalization, ensuring that a single-circuit fault does not affect adjacent units. The main busbar consists of tinned copper bars, verified for temperature rise at 1.1 times the rated current, providing ample operational margin in high-temperature environments.

Blokset LV switchgear on-site installation for industrial project
Standard mechanical and electrical dual interlocks structurally prevent the simultaneous closing of both power sources, completely eliminating the risk of parallel short circuits; the switching logic supports three modes—automatic closing with automatic reset, automatic closing without automatic reset, and fully manual operation—which can be flexibly configured via the controller.
The entire product line complies with the IEC 61439-1/2 standards, has passed internal arc testing in accordance with IEC 61641, and can withstand seismic intensities up to 9 degrees. It is widely used in data centers, medical facilities, process industries, commercial complexes, transportation hubs, and other scenarios with mandatory requirements for power supply continuity.
There are three common types of safety hazards in on-site-assembled, non-standard ATS cabinets, which Blokset Da’s standardized design can directly address.
First, most non-standard cabinets rely solely on electrical interlocks, while their mechanical interlocks have not undergone type testing. Should a component fail or wiring be incorrect, the two power sources may become paralleled, leading to a busbar short-circuit. Blokset Da comes standard with factory-verified dual mechanical and electrical interlocks. The mechanical interlock is physically connected to the circuit breaker’s operating mechanism, making it immune to control circuit failures and eliminating the risk of parallel operation at the hardware level.
Second, custom ATS panels typically do not match the frame of the main distribution panel. When assembled, they are uneven in height, waste floor space, and spare parts are not interchangeable. Blokset Da is fully consistent with the Blokset D feeder panel in terms of cabinet outline, busbar height, and door design, allowing for direct grouping without the need for transition panels. This ensures a neat layout for the entire substation and enables unified management of spare parts inventory.
Third, non-standard cabinets commonly lack temperature rise verification and suffer from cramped cable connection spaces, creating a risk of overheating during full-load operation. The Blokset Da features a standardized 40-module internal layout with ample cable compartment space; the entire series has undergone temperature rise testing at 1.1 times the rated current, ensuring stable temperature rise during long-term operation in a 40°C environment.
| Parameter Category | Specification |
|---|---|
| Rated Operating Voltage Ue | AC 400V / 690V, 50/60Hz |
| Rated Insulation Voltage Ui | AC 1000V |
| Rated Impulse Withstand Voltage Uimp | 12kV |
| Max Main Busbar Current | Up to 6300A |
| Short-Time Withstand Current Icw | 30kA / 50kA / 65kA / 80kA / 100kA, 1s |
| Peak Withstand Current Ipk | 63kA ~ 220kA |
| Form Separation Rating | Up to Form 4 Type 2 |
| Enclosure Protection Degree | IP30 ~ IP54 (indoor) |
| Seismic Rating | Grade 9 |
| Operating Ambient Temperature | -5°C ~ +40°C |
If you need to customize the circuit breaker rating, isolation type, and feeder configuration of the Schneider Blokset Da ATS cabinet based on your project’s operating conditions, please contact our engineering team to obtain a complete configuration list and product quote.
The Blokset Da dual-power-source switchgear supports fully flexible configuration. The main switching components can be either MasterPact MTZ/NT/NW series molded-case circuit breakers (630A–6300A) or Compact NSX series molded-case circuit breakers (100A–1600A); The ATS controller is available in two variants: a basic electromechanical model with LED status indicators, and a Schneider Electric smart model featuring metering, event logging, and Modbus communication capabilities; the compartmentalization levels cover Type 2, Type 3 to Type 4, Class 2. Feeder configurations support multiple wiring schemes, including top-in/top-out, top-in/bottom-out, and bottom-in/bottom-out. The protection rating can be upgraded from the standard IP30 to IP40 or IP54 dust-proof ratings. Additionally, auxiliary components such as first- and first- or second-level surge protectors, multifunctional energy meters, remote I/O communication modules, and simulated panel diagrams, among other auxiliary components, to meet the diverse requirements of different projects.

Schneider Blokset switchgear for highway infrastructure substation
Provides dual-power switching (utility power + generator) for IT critical loads and UPS input circuits, forming a complete power distribution solution when integrated with Blokset feeder cabinets.
Provides reliable power switching for life support systems, emergency lighting, and medical equipment; the dual-interlock design eliminates the risk of parallel operation, ensuring safe power supply for sensitive medical loads.
Used for power switching in continuous production lines, PLC control systems, and critical process equipment; the 9-degree seismic resistance rating is suitable for heavy industrial plant environments.
Provides primary-to-backup power switching for fire protection systems, elevators, and public lighting; its standardized appearance meets the uniform requirements of high-end building electrical rooms.
Ensures uninterrupted power supply for rail transit, airport terminals, and municipal emergency systems.
1. Schneider Electric Officially Authorized Complete Systems
All cabinets are manufactured under Schneider Electric’s certified production system, with 100% of core components made from genuine Schneider Electric materials; each cabinet undergoes comprehensive testing in accordance with factory standards, and all documentation is complete and traceable.
2. Custom Configuration Based on Project Drawings
We strictly match busbar specifications, circuit breaker models, switching logic, and wiring schemes to your single-line diagrams and on-site civil engineering conditions, ensuring no redundant components and no missing or omitted items.
3. Controllable Delivery Timeline
Standard configurations are delivered in 3–4 weeks; customized projects proceed according to a fixed production schedule with weekly progress updates, ensuring no unwarranted delays.
4. End-to-End Technical Support
Our in-house engineering team provides short-circuit withstand verification, distribution room layout review, and on-site commissioning guidance, ensuring full coordination from design to final acceptance.
5. Full Range of Supporting Products
We can simultaneously supply the full range of Blokset cabinet types (feeder cabinets, capacitor compensation cabinets, and motor control centers), enabling centralized procurement for the entire substation and reducing the costs associated with coordinating multiple parties.
Catalogs, CAD drawings and manuals are free — leave your work email and we send the package within 12 hours.
Where Blokset Da delivers — typical on-site installations across industries and regions.
01
02
03
Inquiry