Schneider Electric Authorized Switchgear: Custom Solutions Tailored to Your Order

Schneider Electric authorized ETO custom switchgear for data center, renewable energy, railway and OEM/ODM power distribution, with IEC & UL dual compliance, SLD-based customization, FAT and full project documentation.

WhatsApp

Product Overview

What Is ETO Customization, and What Is the Fundamental Difference Between It and Conventional Selection?

The logic behind conventional switchgear selection is to choose a model from a standard product catalog that closely matches the requirements, and then adapt it to the project’s needs through on-site modifications. ETO (Engineered-to-Order) is the exact opposite: using your single-line diagram (SLD) as the sole core input, all structural parameters—from busbar layout, circuit configuration, and interlock logic to cabinet dimensions and cable entry/exit methods—are reverse-engineered based on this drawing, eliminating any need for compromises involving “hard modifications to standard cabinets.” Every custom cabinet authorized for production by Schneider Electric uses genuine Schneider components, and the cabinet structure strictly adheres to the dual IEC/UL certification system, thereby eliminating at the source common issues associated with custom components, such as certification conflicts and insufficient current-carrying capacity.

OEM/ODM Industrial Power Distribution Scenarios

Product FAT Testing Details

Four Core Scenarios: What Problems Do They Actually Solve at the Electrical Level?

1.Power Distribution Modules for Data Centers

Directly addresses the core challenge of end-point power distribution in data centers: power supply continuity under high circuit density. During customization, we prioritize alignment with your busbar temperature rise calculations. All feeder circuits are configured with coordinated selective protection, ensuring that a short circuit in a single circuit will not trigger the main circuit breaker to trip. Additionally, the system supports a built-in bypass maintenance circuit, allowing for maintenance of individual cabinets without power interruption—fully meeting the requirements for uninterrupted operation and maintenance in data centers.

2.Renewable Energy BOP Power Distribution

Targeted optimization for balance-of-system scenarios in photovoltaic and energy storage power plants. The cabinet structure incorporates design margins for DC components and harmonic tolerance, enabling direct adaptation to the hybrid connection of three different load types: inverter-side, post-combiner box, and auxiliary power. The outdoor-rated cabinet meets the IP54 protection rating by default and features an internal independent air duct cooling design to prevent busbar overheating in high-temperature, dusty outdoor environments.

3.Specialized Power Distribution for Railway Depots

Designed to accommodate the surge load characteristics of railway environments. During the customization phase, the system directly aligns with railway industry power supply standards. It features independent zoning designs for three distinct load types: traction maintenance, yard lighting, and signal power. The cabinets incorporate built-in mechanical and electrical dual interlocks to prevent the under-load tripping of traction circuits caused by operator error, fully meeting the high reliability requirements of railway applications.

4.OEM/ODM Private-Label Power Distribution

Completely separate the power distribution system from your finished product design. We customize the panel screen printing and cabinet labeling according to your brand’s visual requirements. After the entire cabinet passes Schneider Electric’s factory acceptance testing, it is delivered directly to you. You can then install it into your finished product as your own-brand power distribution unit without the need for additional recertification.

OEM/ODM Industrial Power Distribution Scenarios

OEM/ODM Industrial Power Distribution Scenarios

The Complete Delivery Process: What You Need to Do at Each Step

1. Specification Review: You submit three types of documentation—single-line diagrams, on-site installation conditions, and load parameters—and our engineers will complete a manufacturability review within 24 hours. They will directly identify potential issues in the SLD, such as insufficient current-carrying capacity and interlock logic conflicts, while simultaneously providing component selection recommendations.

2. The design verification phase produces complete CAD drawings of the cabinet, secondary circuit schematics, and a bill of materials (BOM) for components. Sheet metal production will not begin until you have signed off on these documents. Since not all parameters are finalized at this stage, any subsequent changes will directly impact the production schedule and costs, making this the most critical milestone in the entire process.

3. After production is completed and the FAT (Factory Acceptance Test) is finished, we will assist you in arranging for engineers to conduct on-site power-up testing for the entire project; alternatively, the entire process can be verified via remote video. The testing covers four core areas: protection setting verification, interlock logic testing, temperature rise simulation, and withstand voltage testing. Shipment will not be arranged until all test items have been signed off as passed; we will absolutely ensure that no issues remain until the on-site energization phase.

4. Delivery of Complete Project Documentation Package Along with the Goods: Includes factory inspection reports, component certificates of conformity, CAD drawings of the cabinet, installation and maintenance manuals, and serial number verification certificates. All documents can be directly imported into the project archiving system.

Hard-coded parameters that directly align with your project requirements

  • Compliance Certification: Supports customized compliance with both IEC and UL standards; no need for additional certification for cross-regional export projects.
  • Minimum Order Quantity: Volume discount pricing applies for orders of 5 units or more. All quotes must be calculated based on your single-line diagram; there is no publicly available standard price list.
  • Authenticity Guarantee: Before payment, you can verify the serial numbers of the cabinet components through Schneider’s official channels; each unit comes with an official Schneider warranty.
  • Delivery Timeframe: Worldwide delivery within 15–30 days. The time required for the design approval process directly determines the total lead time; finalizing the drawings in advance can reduce waiting time by 30%.
  • Technical Support: A dedicated project engineer will serve as your point of contact throughout the process, and written responses to all engineering inquiries will be provided within 12 hours.
  • Request Materials: You can request product catalogs, CAD DWG drawings, and installation manuals free of charge. Please provide your work email address, and we will send them directly within 12 hours.

 

Please feel free to leave us a message and provide your single-line diagram (SLD), functional specifications, or equipment load table. Our electrical systems application engineers will review the protection coordination plan, calculate the required switchroom floor space, and provide a Schneider Electric bill of materials (BOM) and engineering proposal that fully meet your requirements within 24 hours.

 

Key Features

  • Engineered to your single-line diagram
  • IEC and UL dual-compliance available
  • Factory acceptance test (FAT) before shipment
  • OEM / ODM branding supported

Documentation

Catalogs, CAD drawings and manuals are free — leave your work email and we send the package within 12 hours.

Application Scenarios

Where Engineered-to-order packages for data centers, renewables, rail and OEM/ODM requirements. delivers — typical on-site installations across industries and regions.

Data Center Power Module Applications

01

Data Center Power Module Applications

New Energy BOP Power Distribution Scenarios

02

New Energy BOP Power Distribution Scenarios

Power Distribution Scenarios at Railway Rolling Stock Depots

03

Power Distribution Scenarios at Railway Rolling Stock Depots