Ring Main Unit

Schneider SM AirSeT 24kV SF6-Free RMU Supplier

Genuine Schneider SM AirSeT SF6-free RMU switchgear up to 24kV. Compact modular design with zero greenhouse gas. Consult engineering for project sizing.

WhatsApp

Product Overview

Schneider SM AirSeT: SF6-Free MV Switchgear for Secondary Distribution

The Schneider Electric SM AirSeT is a modular, air-insulated medium voltage switchgear for secondary distribution networks up to 24 kV. It replaces SF6 gas with a combination of pure air insulation and vacuum interrupter technology, eliminating the greenhouse gas footprint of conventional MV switchgear while maintaining the same footprint and performance as gas-insulated alternatives.

The switchgear uses EvoPacT vacuum circuit breakers for load-break and fault interruption. The vacuum interrupter handles arc quenching inside a sealed envelope, while the main insulation system uses filtered, pressurized dry air at low pressure. There is no SF6, no fluorinated alternative gas, and no gas-handling equipment required during installation or servicing.

Designed for commercial buildings, industrial plants, and utility secondary substations, the SM AirSeT fits into the same 375 mm and 500 mm wide cubicle envelopes as conventional RM6 and SM6 units. It is fully compatible with EcoStruxure for condition monitoring, energy metering, and remote operation. Internal arc classification up to IAC AFL 12.5 kA 1s is available, meeting standard substation safety requirements.

For EPC contractors and panel builders, the SM AirSeT reduces lifecycle environmental reporting burden, simplifies end-of-life disposal, and avoids future carbon-tax exposure on SF6 equipment. No gas leak detection systems, no gas refilling schedules, and no specialized PPE for gas handling during routine maintenance.

Why Choose SM AirSeT? 3 Key Advantages Over SF6 Switchgear

Selling Point 1: Eliminate SF6 Carbon Exposure

  • Pain point: SF6 has a GWP of 23,500. Under EU F-Gas regulations and similar national policies, installing SF6-insulated MV switchgear locks in decades of compliance, reporting, and disposal liabilities.
  • Solution: SM AirSeT uses pure air (GWP = 0) for insulation and vacuum for arc interruption. The entire medium-voltage circuit contains no fluorinated greenhouse gas.
  • Proof: Zero SF6 across the full voltage and current range. End-of-life recycling is standard metal and plastics processing — no gas recovery, no certified disposal chain required.

Selling Point 2: Same Footprint, Same Grid Performance

  • Pain point: Green alternatives historically required larger switchroom footprint or derated short-circuit capacity, forcing civil works redesign.
  • Solution: The SM AirSeT matches the dimensions and electrical ratings of conventional SF6 RM6/SM6 cubicles — 375 mm width for feeder units, 500 mm for breaker units, 20 kA / 3s short-time withstand.
  • Proof: Drop-in replacement for most retrofit projects. No switchroom expansion needed. Rated current up to 630 A covers the majority of secondary distribution feeders.

Selling Point 3: Digital Condition Monitoring Built-In

  • Pain point: Conventional MV switchgear requires scheduled infrared inspections and manual thermography, which means planned outages and safety risks.
  • Solution: SM AirSeT integrates with EcoStruxure Power Monitoring. Temperature sensors, partial discharge monitoring, and circuit breaker wear counters feed data directly to SCADA or cloud dashboards.
  • Proof: Predictive maintenance schedules replace time-based intervals. Relay settings and event logs are accessible remotely without opening the cubicle.

SM AirSeT Technical Specifications: Ratings, Dimensions & Standards

 

Electrical Ratings
Rated Voltage (Ur) Up to 24 kV
Rated Frequency 50 / 60 Hz
Rated Normal Current (Ie) Up to 630 A (busbar / feeder)
Rated Short-Time Withstand 20 kA / 3 s
Rated Peak Withstand Current 50 kA
Rated Short-Circuit Breaking Current 20 kA
Insulation Levels
Power Frequency Withstand (common) 50 kV / 1 min
Power Frequency Withstand (isolating distance) 60 kV / 1 min
Lightning Impulse Withstand 125 kV (1.2/50 μs)
Insulation Medium Pure dry air, GWP = 0
Mechanical & Construction
Cubicle Width 375 mm (RMU / switch units), 500 mm (breaker units)
Circuit Breaker Type EvoPacT vacuum circuit breaker
Internal Arc Classification IAC AFL 12.5 kA / 1 s (optional upgrade)
Protection Rating IP4X (front), IP3X (top / bottom)
Operating Temperature −25 °C to +70 °C
Standards IEC 62271-200, IEC 62271-1

 

Friendly Reminder:Available ratings and options depend on configuration. Contact us to confirm specifications for your project.

 

SM AirSeT Cubicle Types & Configuration Options

  1. Cubicle Types: RMU (ring main unit), load break switch, vacuum circuit breaker unit, metering unit, transformer feeder
  2. Operation: Manual (CD2) or motorized mechanism, 230 V AC / DC control
  3. Internal Arc Rating: Standard IAC AFL 12.5 kA 1s, upgrade to higher ratings for specific projects
  4. Metering: CT / VT packages for revenue metering or protection metering
  5. Communication: EcoStruxure-ready with PowerTag, Easergy T300, or Sepam relay integration
  6. Fuse Combinations: Switch-fuse units for transformer protection, full range of HV fuses available

SM AirSeT Applications: Where SF6-Free Switchgear Fits Best

The SM AirSeT serves as the primary MV switchgear in three core application areas. In commercial buildings — shopping malls, hospitals, data centers — it acts as the secondary substation switchboard, supporting green building certifications and avoiding future F-Gas regulatory exposure. In industrial plants, the air-insulated construction tolerates dust and humidity without gas leak concerns, while the EvoPacT vacuum breaker's 30,000+ mechanical operations reduce maintenance cycles for 24/7 production facilities. In utility secondary networks, ring main units support looped or radial distribution schemes with optional motorized operation for FLISR automation. For solar PV and wind farm collector substations, the SF6-free design helps meet renewable project carbon footprint targets, and the compact 375–500 mm footprint fits inside prefabricated compact substations without increasing enclosure size.

Why Source SM AirSeT from Funator? Lead Time, Pricing & Support

Source your SM AirSeT from Funator for compressed lead times and full procurement transparency. We ship made-to-order units in 15–30 days against Schneider's standard 8–12 week factory lead time, through regional inventory allocation and pre-booked production slots. Our engineering team reviews your single-line diagram and load data to confirm the correct cubicle arrangement, relay settings, and auxiliary configuration within 24 hours. We provide EXW / FOB Shanghai pricing with volume discounts for EPC and panel builder accounts, arrange third-party witnessed FAT by SGS / BV / Intertek on request, and supply routine test reports with every shipment. All units carry an 18-month warranty from dispatch, with 10-year spare parts availability and technical support in English, Spanish, and Arabic. Weekly production status updates are shared until your order leaves our warehouse.

 

SM AirSeT FAQs: Lead Time, Replacement & Warranty Questions

Q1: What is the delivery time for SM AirSeT switchgear?

Standard ring main units (375 mm width, 630 A) are in stock and ship within 5-10 business days. Custom breaker units and extended switchboard arrangements have a factory lead time of 6-10 weeks, depending on configuration.

Q2: Is SM AirSeT a direct replacement for RM6 or SM6?

Yes. The dimensions and electrical ratings are compatible with Schneider RM6 and SM6 series. For retrofit projects, send us your existing nameplate data and we'll confirm the exact equivalent SM AirSeT cubicle arrangement.

Q3: Does SM AirSeT really contain zero SF6?

Yes. The insulation system uses pure dry air, and arc interruption uses vacuum interrupters. There is no SF6, no alternative fluorinated gas, and no gas pressure monitoring required.

Q4: What warranty and after-sales support do you provide?

All Schneider Electric products come with an 18-month warranty from shipment date. We provide technical selection support, relay setting guidance, and commissioning support remotely. Spare parts are available for 10 years.

 

Key Features

  • Sealed-for-life stainless steel tank
  • Extensible on both sides for future feeders
  • Motorization-ready for smart grid automation
  • Compact footprint for kiosk and indoor installation

Documentation

Catalogs, CAD drawings and manuals are free — leave your work email and we send the package within 12 hours.

Application Scenarios

Where SM AirSeT delivers — typical on-site installations across industries and regions.

SM AirSeT Automotive Manufacturing Line Power Distribution Room

01

SM AirSeT Automotive Manufacturing Line Power Distribution Room

SM AirSeT Automotive Manufacturing Line Power Distribution Room

02

SM AirSeT Automotive Manufacturing Line Power Distribution Room

Schneider Electric’s SM AirSeT Production and Assembly Line (Sulfur Hexafluoride-Free)

03

Schneider Electric’s SM AirSeT Production and Assembly Line (Sulfur Hexafluoride-Free)