Made to Order The Schneider Electric SM AirSeT is a modular, air-insulated medium voltage switchgear for secondary distribution networks up to 24 kV. It replaces SF6 gas with a combination of pure air insulation and vacuum interrupter technology, eliminating the greenhouse gas footprint of conventional MV switchgear while maintaining the same footprint and performance as gas-insulated alternatives.
The switchgear uses EvoPacT vacuum circuit breakers for load-break and fault interruption. The vacuum interrupter handles arc quenching inside a sealed envelope, while the main insulation system uses filtered, pressurized dry air at low pressure. There is no SF6, no fluorinated alternative gas, and no gas-handling equipment required during installation or servicing.
Designed for commercial buildings, industrial plants, and utility secondary substations, the SM AirSeT fits into the same 375 mm and 500 mm wide cubicle envelopes as conventional RM6 and SM6 units. It is fully compatible with EcoStruxure for condition monitoring, energy metering, and remote operation. Internal arc classification up to IAC AFL 12.5 kA 1s is available, meeting standard substation safety requirements.
For EPC contractors and panel builders, the SM AirSeT reduces lifecycle environmental reporting burden, simplifies end-of-life disposal, and avoids future carbon-tax exposure on SF6 equipment. No gas leak detection systems, no gas refilling schedules, and no specialized PPE for gas handling during routine maintenance.
| Electrical Ratings | |
|---|---|
| Rated Voltage (Ur) | Up to 24 kV |
| Rated Frequency | 50 / 60 Hz |
| Rated Normal Current (Ie) | Up to 630 A (busbar / feeder) |
| Rated Short-Time Withstand | 20 kA / 3 s |
| Rated Peak Withstand Current | 50 kA |
| Rated Short-Circuit Breaking Current | 20 kA |
| Insulation Levels | |
|---|---|
| Power Frequency Withstand (common) | 50 kV / 1 min |
| Power Frequency Withstand (isolating distance) | 60 kV / 1 min |
| Lightning Impulse Withstand | 125 kV (1.2/50 μs) |
| Insulation Medium | Pure dry air, GWP = 0 |
| Mechanical & Construction | |
|---|---|
| Cubicle Width | 375 mm (RMU / switch units), 500 mm (breaker units) |
| Circuit Breaker Type | EvoPacT vacuum circuit breaker |
| Internal Arc Classification | IAC AFL 12.5 kA / 1 s (optional upgrade) |
| Protection Rating | IP4X (front), IP3X (top / bottom) |
| Operating Temperature | −25 °C to +70 °C |
| Standards | IEC 62271-200, IEC 62271-1 |
Friendly Reminder:Available ratings and options depend on configuration. Contact us to confirm specifications for your project.
The SM AirSeT serves as the primary MV switchgear in three core application areas. In commercial buildings — shopping malls, hospitals, data centers — it acts as the secondary substation switchboard, supporting green building certifications and avoiding future F-Gas regulatory exposure. In industrial plants, the air-insulated construction tolerates dust and humidity without gas leak concerns, while the EvoPacT vacuum breaker's 30,000+ mechanical operations reduce maintenance cycles for 24/7 production facilities. In utility secondary networks, ring main units support looped or radial distribution schemes with optional motorized operation for FLISR automation. For solar PV and wind farm collector substations, the SF6-free design helps meet renewable project carbon footprint targets, and the compact 375–500 mm footprint fits inside prefabricated compact substations without increasing enclosure size.
Source your SM AirSeT from Funator for compressed lead times and full procurement transparency. We ship made-to-order units in 15–30 days against Schneider's standard 8–12 week factory lead time, through regional inventory allocation and pre-booked production slots. Our engineering team reviews your single-line diagram and load data to confirm the correct cubicle arrangement, relay settings, and auxiliary configuration within 24 hours. We provide EXW / FOB Shanghai pricing with volume discounts for EPC and panel builder accounts, arrange third-party witnessed FAT by SGS / BV / Intertek on request, and supply routine test reports with every shipment. All units carry an 18-month warranty from dispatch, with 10-year spare parts availability and technical support in English, Spanish, and Arabic. Weekly production status updates are shared until your order leaves our warehouse.
Standard ring main units (375 mm width, 630 A) are in stock and ship within 5-10 business days. Custom breaker units and extended switchboard arrangements have a factory lead time of 6-10 weeks, depending on configuration.
Yes. The dimensions and electrical ratings are compatible with Schneider RM6 and SM6 series. For retrofit projects, send us your existing nameplate data and we'll confirm the exact equivalent SM AirSeT cubicle arrangement.
Yes. The insulation system uses pure dry air, and arc interruption uses vacuum interrupters. There is no SF6, no alternative fluorinated gas, and no gas pressure monitoring required.
All Schneider Electric products come with an 18-month warranty from shipment date. We provide technical selection support, relay setting guidance, and commissioning support remotely. Spare parts are available for 10 years.
Catalogs, CAD drawings and manuals are free — leave your work email and we send the package within 12 hours.
Where SM AirSeT delivers — typical on-site installations across industries and regions.
01
02
03
Inquiry