01
Medium Voltage Switchgear
The 24 kV extension of the MVnex platform — higher insulation level for utility grids and large industrial plants, with the same footprint logic and accessories.
In Stock Schneider Electric MVnex-24 is an indoor, air-insulated, metal-clad switchgear solution designed for 24 kV primary power distribution in substations, industrial facilities and infrastructure projects. It uses withdrawable HVX vacuum circuit breakers for switching and fault interruption, with service, test and disconnected positions to support operation and maintenance. The enclosure features separate compartments for busbars, circuit breakers, cables and low-voltage controls, together with mechanical and electrical interlocks. Configurations can include incoming and outgoing feeders, bus couplers, metering and voltage transformer panels. Rated current, short-circuit withstand capacity, protection devices and dimensions are selected according to the project single-line diagram and technical requirements.

1. SF6-Free Insulation: Air provides primary insulation, eliminating the need for SF6 gas in the specified configuration.
2. Reliable Vacuum Interruption: The sealed vacuum interrupter extinguishes switching arcs, ensuring reliable fault interruption and reduced contact erosion.
3. Simplified Maintenance: No SF6 gas filling, leakage monitoring or gas recovery is required for this configuration.
4. Operational Safety: Mechanical interlocks, shutters and earthing switches help prevent unsafe operating sequences.
5. Environmental Benefits: Avoids the use of SF6, a high-global-warming-potential insulating gas, in the specified configuration.
Note: Routine inspection of operating mechanisms, contacts, relays and other electrical components is still required.

| Electrical Specifications | |
|---|---|
| Rated Voltage | 24 kV |
| Power Frequency Withstand Voltage | 65 kV / 1 min |
| Lightning Impulse Withstand Voltage | 125 kV Peak |
| Rated Current | 630–1250 A, 2500 A |
| Rated Short-Time Withstand Current | 25–31.5 kA / 4 s |
| Rated Peak Withstand Current | 63–80 kA |
| Protection Rating | External Enclosure: IP4X; Compartments: IP2X |
| Standard Panel Dimensions | |
| 630/1250 A – 31.5 kA | Width: 800 mm × Height: 2400 mm × Depth: 2260 mm |
| 2500 A – 31.5 kA | Width: 1000 mm × Height: 2400 mm × Depth: 2260 mm |
| Cable Entry Depth | Top Entry: 1860 mm; Bottom Entry: 1860 mm |
| Operating Conditions | |
| Operating Temperature | -15°C to +40°C |
| Maximum Installation Altitude | ≤ 1000 m |
| Relative Humidity | 24-hour average: ≤ 95%; Monthly average: ≤ 90% |
Note:Specifications and dimensions are based on the provided product information. Actual values may vary depending on voltage rating, panel configuration, current rating and installation requirements. Please confirm the final dimensions and technical ratings against the approved drawings, and contact us for further technical assistance or product inquiries.
MVnex-24 is designed for indoor medium-voltage power distribution in industrial, commercial and infrastructure projects.
Power Substations
Suitable for HV/MV and MV/MV substations, incoming feeders, outgoing feeders and busbar sectionalizing.
Industrial Power Distribution
Used in metallurgy, cement production, petrochemical facilities, manufacturing plants and electronics factories.
Data Centers
Supports medium-voltage power receiving, feeder protection and distribution systems for critical data center infrastructure.
Water Treatment Facilities
Suitable for medium-voltage distribution systems supplying pumps, motors and auxiliary equipment in water treatment plants.
Transportation Infrastructure
Applicable to railway power distribution, airports, ports, tunnels and other infrastructure facilities.

Funator provides project-oriented Schneider MVnex-24 sourcing and technical coordination for international power distribution projects.
Configuration Review: We check the single-line diagram, panel schedule, breaker ratings, CT/VT ratios and protection requirements before quotation.
Technical Documentation: Support includes datasheets, general arrangement drawings, wiring diagrams, bills of materials and applicable test documents.
Component Matching: We coordinate HVX vacuum circuit breakers, protection relays, measuring devices and accessories according to the approved configuration.
Export Support: We coordinate production schedules, pre-shipment inspection, export packing and international delivery.
Project-Based Supply: Stock availability and lead time are checked against the actual 24kV panel configuration rather than assumed from generic product listings.
Contact Funator with your single-line diagram and panel list for a project-specific technical and commercial quotation.
1. What is the delivery time for Schneider MVnex-24 switchgear?
Delivery time depends on panel quantity, HVX circuit breaker availability, selected components and drawing approval. A confirmed lead time will be provided after technical specifications and order details are finalized.
2. Can I get a quotation for MVnex-24 based on my project drawings?
Yes. Send us your single-line diagram (SLD), panel schedule and technical specifications. We can review the configuration and prepare a project-specific technical and commercial quotation.
3. What is the price of Schneider MVnex-24 24kV switchgear?
Pricing depends on rated current, short-circuit capacity, panel configuration, vacuum circuit breakers, protection relays and accessories. Contact us for a quotation based on your project requirements.
4. Do you provide international shipping for MVnex-24 switchgear?
Yes. Export packing and international shipping can be arranged according to the destination, shipment volume and delivery terms. FOB, CIF and DDP options can be discussed for eligible destinations.
5. What technical documents are available before ordering?
Typical project documents include technical datasheets, general arrangement drawings, single-line diagrams, wiring diagrams, bills of materials and applicable test reports. Document availability depends on the selected configuration.
6. Can MVnex-24 be customized for different power distribution projects?
Yes. Panel arrangements, busbar ratings, HVX breaker specifications, CT/VT ratios, protection relays and auxiliary control circuits can be selected according to the approved project requirements.
7. What warranty and after-sales support are available?
Warranty terms are confirmed according to the manufacturer's warranty policy and sales contract. Technical documentation, troubleshooting coordination and spare parts support can be arranged subject to the agreed service scope.
Catalogs, CAD drawings and manuals are free — leave your work email and we send the package within 12 hours.
Where MVnex-24 delivers — typical on-site installations across industries and regions.
01
02
03
Inquiry