Ring Main Unit
Schneider RM AirSeT is an SF6-free ring main unit for medium voltage distribution up to 24 kV. It combines pure air insulation with vacuum interruption, with optional digital monitoring and remote control.
Made to Order RM AirSeT brings pure-air insulation to the compact RMU format, giving 12 kV secondary networks an SF₆-free option without redesigning the kiosk or the civil works. It replaces legacy RM6 installations on a like-for-like footprint.
As a made-to-order model, RM AirSeT is configured per project — switching functions, protection relays and metering built to your network standard, with full factory testing before dispatch.


| Insulation Level - Voltage Withstands | |||||
|---|---|---|---|---|---|
| Parameter | Symbol | Description / Test Condition | Unit | 12 kV | 24 kV |
| Rated Voltage | Ur | kV | 12 | 24 | |
| Rated Frequency | fr | Hz | 50/60 | ||
| Rated Short-Duration Power-Frequency Withstand Voltage | Ud | Phase-to-Phase and Phase-to-Earth | kV (1 min RMS) | 28 | 50 |
| Across the Isolating Distance | kV (1 min RMS) | 32 | 60 | ||
| Rated Lightning Impulse Withstand Voltage | Up | Phase-to-Phase and Phase-to-Earth | kV (1.2 μs) | 75 | 125 |
| Across the Isolating Distance | kV (1.2 μs) | 85 | 145 | ||
| Insulation and Switching | |||||
| Insulation Medium | Busbar Disconnectors, Earthing Switch | Pressurised Pure Air (1) | |||
| Air Relative Filling Pressure | At 20 °C | MPa | 0.04 | 0.15 | |
| Disconnecting Principle | In pressurised pure air, compartment sealed from ambient conditions | Three-Position Disconnector | |||
| Switching and Breaking Medium | Vacuum | ||||
| Mechanical Endurance | As per IEC | Endurance Class "Extended" | |||
| Current | |||||
| Rated Current | Ir | Busbar | 630 A | ||
| Short-Time Withstand Current | Ik/Ike | kA | 20 (2) / 20 (2) | ||
| Duration | tk/tke | s | 1 s or 3 s / 1 s | ||
| Rated Peak Withstand Current | Ip | kA | 52 (2) | ||
| Service Continuity Class as Defined in IEC 62271-200 | |||||
| Other High-Voltage Compartments or Functions May Remain Energised | LSC 2: Access to the cable compartment when the busbar is energised is possible | LSC 2 | |||
| Internal Partitions Between Compartments | PM: Metallic Earthed | PM | |||
| Degrees of Protection Provided by Enclosure | |||||
| External Enclosure | As per IEC 60529 - Protection of Active Medium-Voltage Circuits (Tank) | IP67 | |||
| External Enclosure | Protection of MV Cable Compartment | IP4X | |||
| External Enclosure | Access to Mechanism | IP4X | |||
| External Enclosure | Protection of LV Auxiliary Components | IP4X | |||
| Internal Protection | As per IEC 60529 - Index Between Compartments | IP2X | |||
| Degree of Protection Against Mechanical Impacts | |||||
| IK Code | Class as per IEC 62262 | IK07 | |||
| Internal Arc Fault Withstand | |||||
| Basic | Sealed Compartment Equipped with a Safety Membrane | Not Classified | |||
| Internal Arc Classification (IAC) | IA | Class A AFLR - Front, Lateral and Rear Access | kA | 20 kA AFLR (3) | |
| Duration | tA | s | 1 s | ||
| Gas Relief |
|
||||
Note:Specifications and dimensions are based on the provided product information. Actual values may vary depending on voltage rating, panel configuration, current rating and installation requirements. Please confirm the final dimensions and technical ratings against the approved drawings, and contact us for further technical assistance or product inquiries.
RM AirSeT design is the optimal choice for Electrical Distribution Companies and
Distribution Service Operators worldwide. It also provides more versatility for industrial, infrastructures, buildings or residential networks.Traditional Ring Main Unit (RMU for MV/LV kiosk or MV switching Substation)
MV renewable distributed generation
Automatic-fast-Transfer of Sources (ATS)
Feeders to overhead lines (including reclosing sequences)


Does RM AirSeT use SF6 gas?
No. It uses pure air insulation and vacuum interruption, eliminating the need for SF6 or alternative insulating gas mixtures.
What voltage and current ratings are available?
The 12–24 kV range offers a rated busbar current of 630 A. Short-circuit ratings depend on the voltage and selected configuration.
Can RM AirSeT replace an existing SF6 ring main unit?
It can be considered for retrofit projects. Dimensions, cable connections, electrical ratings and protection requirements must be checked before confirming a replacement.
Can it support remote monitoring and control?
Yes. Optional sensors, motorized mechanisms and communication equipment enable condition monitoring and integration with distribution automation systems.
Can additional feeders be added later?
Expandable versions support additional compatible units. Specify future feeder requirements when ordering so the correct extension arrangement can be selected.
What information is needed for a quotation?
Send your single-line diagram, voltage, rated current, fault level and feeder configuration. Include protection requirements, installation conditions and delivery location.
Catalogs, CAD drawings and manuals are free — leave your work email and we send the package within 12 hours.
Where RM AirSeT delivers — typical on-site installations across industries and regions.
01
02
03
Inquiry