01
Industrial Control & Distribution
Genuine Schneider Square D UL-certified low voltage switchboards & switchgear (QED-2, PZ4). Custom NEMA enclosures & busbar ratings. Get SLD & B2B quote.
In Stock This series consists of genuine Schneider Square D U.S. standard low-voltage distribution products, divided into two main categories: UL 67-certified panelboards and UL 891-certified low-voltage switchboards. They have each completed a full set of type tests in accordance with UL 67, UL 891 standards, comply with the requirements of the National Electrical Code (NEC), and have also obtained CSA certification.
Product rated voltages range from 120/240 V to 600Y/347 V AC, with main circuit rated currents from 100 A to 6,000 A. making them suitable for markets such as North America and Latin America that follow U.S. electrical standards. They are used for system feeder distribution, branch circuit protection, and energy metering, and can be factory-matched with the full range of Square D terminal components, including PowerPacT molded-case circuit breakers, Masterpact frame-mounted circuit breakers, metering modules, and surge protectors.
1. UL 67/UL 891 Standard Compliance Certification
The cabinet and all accompanying components bear valid UL Listing marks, and their serial numbers can be traced and verified in the official database. The installation dimensions, busbar current-carrying capacity, and short-circuit breaking parameters are fully consistent with Schneider Electric’s official catalog specifications. The complete assembly requires no on-site modifications and meets local electrical acceptance requirements.
2. I-Line Plug-in Busbar Design Principle
Circuit breakers are directly snapped into the busbar system, eliminating bolted connection points. Contact resistance remains stable, and long-term operating temperature rise strictly complies with UL limit standards; replacing a single-circuit component takes ≤5 minutes, and circuit expansion requires no disassembly or modification of the busbar system, resulting in minimal on-site maintenance and retrofitting efforts.
3. Comprehensive Short-Circuit Breaking Capacity Coverage
Branch circuit short-circuit breaking capacity ranges from 10 kA to 200 kA, with the main circuit supporting a maximum breaking capacity of 200 kA; selection can be based on project-specific short-circuit current calculations, and complete calculation documentation for derating margins is provided, making it suitable for all load scenarios—from light-duty commercial to heavy-duty industrial applications.
4. NEMA Protection Ratings and OSHPD Seismic Certification
Enclosure protection covers the full range of NEMA ratings: NEMA 1 (general indoor use), NEMA 3R (outdoor rain-resistant), and NEMA 12 (dust- and splash-proof); the entire series has passed OSHPD seismic pre-certification and complies with IBC and ASCE seismic standards, making it suitable for infrastructure projects with high requirements.
5. Modular, Universal Design and Scalability
Utilizing standardized American installation dimensions and circuit modules, components are interchangeable with UL-certified products that meet the same standards; metering modules, surge protectors, and smart communication modules support in-place expansion without requiring modifications to the cabinet structure, ensuring controllable costs for future upgrades.
| Technical Parameter | NQ/NF General Panelboard | I-Line Heavy-Duty Panelboard | QED Series Switchboard |
|---|---|---|---|
| Standard Compliance | UL 67, CSA C22.2 | UL 67, CSA C22.2 | UL 891, CSA C22.2 |
| Rated Operational Voltage (Ue) | 240V / 480V / 600Y/347V AC | 240V / 480V / 600Y/347V AC | 240V / 480V / 600V AC |
| Main Bus Rated Current (In) | 100A – 800A | 400A – 1200A | 1000A – 6000A |
| Rated Short-Circuit Breaking Capacity | 10kA – 65kA | 65kA – 200kA | 65kA – 200kA |
| Enclosure Type (NEMA Rating) | NEMA 1 / 3R / 12 | NEMA 1 / 3R / 12 | NEMA 1 / 2 / 12 |
| Mounting Type | Flush / Surface-mounted | Flush / Surface-mounted | Floor-standing |
| Compatible Devices | QO / PowerPacT circuit breakers | PowerPacT MCCBs | PowerPacT MCCBs / Masterpact ACBs |
| Seismic Certification | OSHPD certified, IBC/ASCE compliant | OSHPD certified, IBC/ASCE compliant | OSHPD certified, IBC/ASCE compliant |
Please provide the cabinet type, rated current, breaking capacity, protection rating, and purchase quantity you require, and we will respond within 24 business hours with a comprehensive technical and commercial proposal and an itemized quote.
- Commercial Buildings: Main service and floor distribution for office buildings, shopping centers, and hotels, meeting UL and NEC compliance and acceptance requirements
- Data Centers: Low-voltage main distribution rooms and row-end cabinet distribution, suitable for high-reliability continuous power supply scenarios
- Industrial Manufacturing: Low-voltage feeders, power circuits, and motor load protection in production workshops, suitable for heavy-duty operating conditions
- Infrastructure: Low-voltage power distribution systems in hospitals, transportation hubs, and municipal facilities, compliant with local infrastructure acceptance standards
- Residential and Small-Scale Commercial: In-unit power distribution and branch circuit distribution for apartment buildings, convenience stores, and restaurants
- Renewable Energy Applications: Low-voltage-side power distribution and protective circuits for grid-connected photovoltaic systems and energy storage systems

Schneider Square D QED series UL 891 low voltage switchboard
1. Guaranteed Genuine Factory Products with Zero Risk of Specification Deviations
All enclosures and circuit breakers are genuine Square D components, and their UL listing numbers can be verified through official channels. Before assembly, we verify the busbar current-carrying capacity, breaking capacity, and cutout dimensions for each unit individually. No non-standard modifications are made throughout the process, eliminating on-site adaptation issues.
2. Delivery Time Reduced by 60% Compared to Direct Purchases from the Manufacturer
Standard UL distribution panels are kept in stock and can be shipped within 7 days; custom-assembled panels have a delivery cycle of 8–12 weeks, far superior to the manufacturer’s standard 40-week lead time. Upon order confirmation, we immediately provide a fixed production schedule and shipping plan, ensuring traceable delivery milestones.
3. 100% Factory Acceptance Testing (FAT) in Compliance with UL Standards
Every unit undergoes a comprehensive inspection strictly following UL factory test procedures, including insulation resistance, loop resistance, powered operation verification, and random sampling of mechanical operations. We support on-site customer witnessing or third-party FAT inspections, and formal test records are issued upon completion.
4. Delivery of a Complete Set of Compliance Documentation
UL/CSA type test reports, original manufacturer’s certificates of conformity for components, factory test records, and certificates of origin are provided with the shipment. This fulfills all documentation requirements for local electrical acceptance and customs clearance, reducing the workload associated with project approval.
5. Localized After-Sales Support for North American Projects
All components are covered by Schneider Electric’s global manufacturer’s warranty, supplemented by an additional 1 year of localized technical support from Funator; standard spare parts can be delivered to major North American ports within 7–10 days, technical issues are resolved within 24 hours, and on-site installation and commissioning services are available.
A: Yes. All enclosures and components are genuine Schneider Electric Square D products with valid UL listing numbers, which can be verified in the official UL certification database. Complete certification documents can be provided prior to shipment for project approval.
A: Standard stock items ship within 7 days; custom complete panels are delivered in 8–12 weeks, a significant reduction compared to the manufacturer’s standard 40-week lead time. A fixed production schedule is issued upon order confirmation, and any changes to the delivery date will be notified in writing 3 business days in advance.
A: Official exterior diagrams, primary circuit diagrams, and installation manuals are available for the entire product line. Project-specific drawings (including layout diagrams and cutout diagrams) will be provided within 3 business days after order confirmation and can be used to support detailed design work.
Catalogs, CAD drawings and manuals are free — leave your work email and we send the package within 12 hours.
Where UL-Certified Power Distribution Cabinets delivers — typical on-site installations across industries and regions.
01
02
03
Inquiry