Medium Voltage Switchgear
Proven air-insulated MV switchgear up to 24 kV, valued worldwide for its robustness in utility, infrastructure and heavy industrial applications.
In Stock Schneider Electric PIX is an indoor medium voltage switchgear solution for utility networks, industrial plants and infrastructure projects. As a reliable Schneider PIX supplier, Funator provides product selection, technical support and competitive quotations.
Available in 12 kV, 17.5 kV and 24 kV versions, PIX features metal-enclosed construction, air insulation and vacuum switching technology. It supports withdrawable vacuum circuit breakers, busbar systems, instrument transformers and earthing switches. Selected configurations use the EvoPacT HVX vacuum circuit breaker for reliable switching and protection. Designed for indoor substations and MV distribution rooms, PIX offers flexible panel configurations and integrated safety interlocking.

| Parameter | Specification |
|---|---|
| Rated Voltage | 7.2 / 12 / 17.5 / 24 kV |
| Rated Current | 630–4000 A (standard); 5000 / 6300 A (special high-capacity configurations) |
| Short-Circuit Breaking Capacity | 12 kV: 25–50 kA; 24 kV: 25–40 kA (common ratings) |
| Rated Frequency | 50 Hz |
| Degree of Protection | Enclosure: IP4X; Compartments: IP2X |
| Internal Arc Classification | AFLR, 50 kA, 1 second |
| Loss of Service Continuity | LSC 2B-PM |
| Installation Method | Front-accessible and rear-accessible installation |
| Cable Entry | Top and bottom cable entry available |
| Parameter | Specification |
|---|---|
| PIX 550 Dimensions | 550 × 1400 × 2250 mm (W × D × H) |
| PIX 550 Cabinet Width | 550 mm |
| Floor Space | Approximately 0.77 m² |
| Standard Cabinet Height | 2250 / 2400 mm |
| Height with Arc Duct | 2850 / 3000 mm |
| Common Cabinet Widths | 550 / 650 / 800 / 1000 mm |
| High-Current Cabinet Design | Greater cabinet depth may be required for high-current configurations. |
Note:Specifications and dimensions are based on the provided product information. Actual values may vary depending on voltage rating, panel configuration, current rating and installation requirements. Please confirm the final dimensions and technical ratings against the approved drawings, and contact us for further technical assistance or product inquiries.
Air-Insulated Design and Vacuum Switching
The PIX Standard configuration uses air for insulation and vacuum technology for arc interruption, eliminating SF6 as the primary insulating and arc-quenching medium. Confirm the SF6-free design against the specific PIX version and breaker configuration.
Reliable Vacuum Circuit Breaker Technology
PIX can be equipped with Schneider Electric EvoPacT HVX vacuum circuit breakers. The sealed vacuum interrupter extinguishes electrical arcs during switching and fault interruption, reducing routine maintenance requirements.
Withdrawable Functional Design
The withdrawable breaker truck moves between service and disconnected positions, allowing inspection, isolation and maintenance without removing the complete switchgear panel.
Enhanced Operational Safety
Mechanical and electrical interlocks prevent incorrect switching sequences. Voltage detection systems and earthing switches support safe operation and maintenance.
Flexible Monitoring and Protection
Depending on the configuration, PIX supports protection relays, voltage and current transformers, partial discharge monitoring and condition monitoring devices to help detect potential faults and assess equipment condition.
Tested Metal-Enclosed Construction
PIX configurations are designed and type-tested according to applicable IEC 62271 requirements. Internal arc classification and safety ratings depend on the selected panel configuration and supporting test reports.
Utility Substation
Schneider PIX medium voltage switchgear installed in a utility substation for reliable power distribution and feeder protection.
Feeder Protection and Distribution
Schneider PIX24 outgoing feeder panel equipped with protection relays, metering devices and circuit breaker control systems for medium voltage distribution.
Industrial Switchgear Installation
A lineup of Schneider PIX Easy medium voltage switchgear panels arranged for industrial power distribution and centralized electrical control.

1. Availability Verification
We check PIX panel, EvoPacT HVX circuit breaker and accessory availability according to your required configuration.
2. Project Delivery Support
We coordinate technical confirmation, drawing approval, production scheduling and export delivery. Delivery references can be provided where available.
3. Technical Documentation
We support GA drawings, single-line diagrams, technical datasheets and available type-test reports.
4. Strong Supply Chain
Backed by HEJI GROUP, with 43+ subsidiaries, 1,800+ employees and 15 warehouses across China, Funator provides reliable sourcing and project supply support.
1. What voltage ratings are available for Schneider PIX?
PIX Standard covers 12 kV, 17.5 kV and 24 kV applications. The selection depends on network requirements.
2. Is Schneider PIX an SF6-free switchgear?
The air-insulated configuration with vacuum circuit breakers uses air for insulation and vacuum for arc interruption, without SF6 as the primary medium.
3. Which circuit breaker is used in Schneider PIX?
Designated configurations use Schneider Electric EvoPacT HVX withdrawable vacuum circuit breakers.
4. What is the maximum rated current of Schneider PIX?
Referenced PIX Standard ratings reach 3,150 A for PIX 12/17 and 2,500 A for PIX 24, depending on configuration.
5. Does Schneider PIX comply with IEC 62271-200?
PIX configurations are designed and type-tested against applicable IEC 62271 requirements. Relevant test reports should be confirmed before ordering.
6. What applications is Schneider PIX suitable for?
PIX is designed for indoor MV power distribution in industrial plants, utility substations, power stations and infrastructure projects.
Catalogs, CAD drawings and manuals are free — leave your work email and we send the package within 12 hours.
Where PIX delivers — typical on-site installations across industries and regions.
01
02
03
Inquiry