Medium Voltage Switchgear

Schneider PIX550 12kV Switchgear | 550mm HVX AIS

Schneider PIX550 is a compact 12kV air-insulated switchgear featuring HVX vacuum circuit breakers, designed for reliable medium-voltage power distribution.

WhatsApp

Product Overview

Schneider PIX550 12kV Compact Air-Insulated Medium Voltage Switchgear

Schneider Electric PIX550 is a compact 12kV air-insulated medium voltage switchgear featuring an embedded-pole HVX vacuum circuit breaker. Its 550mm cabinet width and high-current busbar design make it suitable for commercial buildings, data centers, substations and industrial power distribution.

Schneider Switchgear Structure

 Schneider Switchgear Structure

Core Technical Advantages of Schneider PIX550: Compact Design and Vacuum Switching

1. Compact 550mm Cabinet Design

- The PIX550 cabinet is only 550mm wide, reducing installation space in electrical rooms.
- Suitable for commercial substations, building retrofits and compact E-house installations.
- Panels can be connected without additional busbar transition sections in supported arrangements.

2. Embedded-Pole HVX Vacuum Circuit Breaker

- Uses Schneider HVX vacuum interruption technology for switching and fault protection.
- Embedded poles provide additional insulation protection against external environmental conditions.
- The contact design supports stable current transfer and effective heat dissipation.

3. High Short-Circuit Withstand Capacity

- Rated short-time withstand current of 31.5kA for 4 seconds.
- Rated peak withstand current of 80kA.
- Internal arc withstand capability of 31.5kA for 1 second, subject to the tested configuration.

4. Air Insulation and Reduced SF6 Dependence

- Air provides insulation between the primary conductors.
- Vacuum interrupters extinguish switching arcs without using SF6 gas.
- SF6-specific gas handling for these functions is unnecessary. The complete assembly must be verified before making a formal SF6-free claim.

5. Verified Mechanical and Thermal Performance

- Schneider Electric lists temperature-rise testing at 1.1 times rated current.
- Additional validation includes high- and low-temperature, condensation and seismic testing.
- The applicable qualification records should be checked for the offered panel configuration.

6. Flexible Installation and Maintenance

- Supports top cable or busbar entry, subject to panel design.
- Compact construction simplifies switchroom planning.
- Panel accessibility, maintenance clearance and operating interlocks must be checked during engineering.

Schneider PIX550 Technical Specifications and Electrical Ratings

Core Electrical Specifications
Product Model Schneider Electric PIX550
Product Type Air-Insulated Medium Voltage Switchgear
Product Voltage Range 12–24 kV
Rated Voltage (Detailed Listed Rating) 12 kV
Rated Frequency 50 Hz
Power Frequency Withstand Voltage 42 / 48 kV
Lightning Impulse Withstand Voltage (BIL) 75 / 85 kV
Rated Current Up to 1250 A
Maximum Main Busbar Current Up to 4000 A
Rated Peak Current 80 kA
Rated Short-Time Withstand Current 31.5 kA (Manufacturer reference: (4))
Internal Arc Fault Withstand Capability 31.5 kA / 1 s
Protection Degree IP4X
Structure and Configuration
Cabinet Width 550 mm
Basic Cabinet Dimensions (W × D × H) 550 × 1400 × 2250 mm
Front Operating Clearance Approximately 1 m
Circuit Breaker Sealed HVX Vacuum Circuit Breaker
Contact Structure Tulip Contact Structure
Panel Connection Panel Lineup Without Additional Adapter
Design Verification and Environmental Tests
Temperature Rise Test 1.1 Ir
High and Low Temperature Test -25°C to +40°C
Condensation Test -25°C to +40°C
Seismic Test Performed
Typical Applications
Commercial and Public Buildings Commercial Buildings, Public Buildings
Infrastructure Tunnels, Port Equipment, Tower Cranes
Industrial Applications Light Industry, Grid Supporting Projects
Prefabricated Electrical Systems E-House and Prefabricated Substations
Power Distribution Projects

Retrofit Projects and Utility Distribution 

Note: Not sure if Schneider PIX550 12kV switchgear is suitable for your project? Send us your single-line diagram (SLD), technical specifications and electrical requirements. Our team will provide free technical selection support and a formal quotation within 24 business hours.

Where Schneider PIX550 Is Used in Power Distribution Projects

1. Schneider PIX550 for Commercial Building Power Distribution

Used in commercial complexes, shopping malls and office buildings for 12kV primary power distribution, feeder protection and compact electrical room installations.

2. Schneider PIX550 for Data Center Electrical Systems

Suitable for 12kV incoming distribution and transformer feeder protection in data centers where reliable switching and efficient electrical room layouts are required.

3. Schneider PIX550 for Industrial Power Distribution

Applied in manufacturing plants and light industrial facilities to distribute medium-voltage power to transformers, process equipment and auxiliary electrical systems.

4. Schneider PIX550 for Prefabricated E-House Substations

The compact 550mm cabinet design supports space-efficient switchgear layouts inside prefabricated electrical houses and modular substations.

5. Schneider PIX550 for Electrical System Retrofit Projects

Suitable for switchgear replacement or capacity upgrades in existing facilities where electrical room dimensions and access are restricted.

6. Schneider PIX550 for Infrastructure Power Distribution

Used in 12kV power distribution systems serving tunnels, ports, public facilities and utility-related infrastructure, subject to project design requirements.

Schneider PIX550 Water Treatment Plant Power Distribution Application

Schneider PIX550 Water Treatment Plant Power Distribution Application

Why Choose Funator for Schneider PIX550 Switchgear Supply?

Funator provides technical sourcing, configuration review and international supply coordination for Schneider Electric PIX550 medium voltage switchgear.

1. Brand and Model Verification

We check the product model, manufacturer information, HVX breaker configuration and available authorization documentation before order confirmation.

2. Technical Matching

Our team reviews rated voltage, current, short-circuit withstand ratings, panel dimensions, protection functions and installation requirements against the project single-line diagram.

3. Project-Based Pricing

We prepare quotations based on the panel quantity, breaker specifications, protection devices, auxiliary components, documentation and delivery terms. Detailed pricing can be provided after configuration review.

4. Delivery Schedule Coordination

We verify key component availability, production schedules and technical drawing approval before confirming the estimated manufacturing lead time.

5. Pre-Shipment Inspection

We can coordinate visual inspection, component model verification, nameplate checks, wiring inspection, accessories and export packing inspection before shipment.

6. Factory Testing and Reports

Applicable routine tests and factory acceptance testing can be coordinated according to the approved test plan. Available documentation may include routine test records, type-test evidence and technical drawings.

7. International Shipping Support

Export packing, sea freight, air freight and destination-specific logistics can be arranged. Freight quotations and transit estimates are provided according to the shipment details and delivery terms.

8. Warranty and After-Sales Service

Warranty coverage follows the confirmed manufacturer terms and sales contract. Funator coordinates technical troubleshooting, replacement-part enquiries and related after-sales communication.

Frequently Asked Questions About Schneider PIX550 Price, Delivery and Warranty

1. What is the price of Schneider PIX550 12kV switchgear?

The price depends on panel quantity, HVX breaker configuration, protection relays, CT/VT specifications and optional components. Send your single-line diagram and panel schedule to receive an itemized project quotation.

2. What is the delivery time for Schneider PIX550 switchgear?

Production lead time depends on component availability, panel configuration, factory scheduling and drawing approval. We will confirm the estimated manufacturing lead time after reviewing your technical specifications and order requirements.

3. Is Schneider PIX550 suitable for a 12kV power distribution system?

Yes. PIX550 is rated at 12kV with a maximum rated current of 1250A and short-time withstand capacity of 31.5kA for 4 seconds. Final selection must match the project fault level and protection requirements.

4. Can PIX550 support a 4000A main busbar?

Yes. Schneider Electric specifies a maximum main busbar current of 4000A for PIX550. However, the individual feeder current is limited to 1250A in the published configuration. Both ratings must be checked separately.

5. Can we inspect the PIX550 switchgear before shipment?

Yes. Inspection arrangements can include cabinet appearance, nameplates, component models, wiring, accessories and packing. Customer-witnessed factory acceptance testing can be discussed and included in the agreed inspection plan.

6. What factory test reports and technical documents are available?

Available documents may include approved drawings, datasheets, wiring diagrams, routine test records and applicable type-test reports. Specific certifications and documentation requirements should be confirmed before placing the order.

7. Do you provide international shipping for Schneider PIX550?

Yes. We can coordinate export packing and international transportation by sea or air. FOB, CIF and DDP options can be discussed depending on the destination, shipment size and customs requirements.

8. What warranty and after-sales support does Funator provide?

Warranty terms follow the manufacturer policy and confirmed sales agreement. Funator can coordinate technical clarification, troubleshooting and spare-parts enquiries. Installation or on-site service requirements should be agreed before ordering.

 

Key Features

  • 550mm cabinet width saves installation space.
  • Uses air as the primary insulating medium.
  • Ensures reliable switching and fault interruption.
  • Enhances insulation protection and operational reliability.

Documentation

Catalogs, CAD drawings and manuals are free — leave your work email and we send the package within 12 hours.

Application Scenarios

Where PIX550 delivers — typical on-site installations across industries and regions.

Schneider PIX550 Data Center Medium Voltage Distribution Application

01

Schneider PIX550 Data Center Medium Voltage Distribution Application

Schneider PIX550 Industrial Medium Voltage Switchgear Application

02

Schneider PIX550 Industrial Medium Voltage Switchgear Application

Schneider PIX550 Industrial Power Distribution Room Application

03