Medium Voltage Switchgear

Schneider GMA Gas-Insulated MV Switchgear (GIS)

Authorized Schneider GMA SeT Series GIS MV switchgear (24kV, 2500A, 31.5kA) with custom PowerLogic P3/P5 relay configuration for EPC, mining & BESS sites.

WhatsApp

Product Overview

Schneider GMA MV Switchgear is part of Schneider’s SeT Series MV Switchgear, commonly referred to as Schneider GMA GIS Switchgear—a compact gas-insulated medium-voltage switchgear with a maximum rated voltage of 24 kV. All live parts of the main circuit are enclosed within a stainless steel sealed gas-insulated compartment. A vacuum arc extinguisher is responsible for breaking the circuit, while the sealing gas provides only phase-to-phase and phase-to-ground insulation and does not participate in arc extinction. The cabinet is divided into a gas-insulated main circuit compartment, a mechanical compartment, a secondary control compartment, and a cable compartment. It features a dual mechanical and electrical five-prevention interlock system, and fault arcs are vented in a rearward direction to ensure the safety of maintenance personnel working at the front of the cabinet.

Schneider GMA GIS Switchgear internal structure, vacuum circuit breaker, busbar connection, cable compartment

The busbars are connected via inter-cabinet plug-in joints, eliminating the need for on-site fabrication of rigid busbars during cabinet assembly and resulting in a shorter installation cycle. The secondary protection circuits are natively compatible with Schneider Electric’s relay protection systems, enabling the implementation of a proven PowerLogic P3 P5 Switchgear protection solution. The entire set of protection parameter settings, communication configurations, and secondary power injection debugging can be delivered simultaneously. Compared to conventional air-insulated armored switchgear, Schneider GMA GIS Switchgear occupies less floor space and offers greater resistance to dust, condensation, and high-humidity, contaminated environments. Many overseas EPC projects prioritize this model; however, it is important to note that it features a permanently sealed design that does not require opening the enclosure for gas replenishment. Therefore, maintenance practices cannot be directly applied from standard GIS switchgear—this is the most common pitfall encountered on-site.

Key Selling Points

Challenge 1: Insufficient space in the switchgear room; existing substations cannot accommodate AIS air-insulated switchgear due to capacity limitations → Solution: Schneider GMA MV Switchgear, which is 25% smaller in volume than traditional GIS with the same specifications and features modular side-by-side expansion;

Challenge 2: High levels of condensation and dust at coastal, mining, and water treatment sites cause insulation components in air-insulated switchgear to accumulate contaminants and experience flashover → Solution: Schneider GMA GIS Switchgear features a fully sealed IP65 main circuit gas compartment, isolating live primary components from the external environment;

Challenge 3: Conventional GIS requires complex procedures for opening the cover to replenish gas and perform leak detection; overseas supervision and acceptance are stringent, and opening the cover voids the original manufacturer’s warranty → Solution: SeT Series MV Switchgear—this model features a “Sealed for Life” welded seal structure, and the standard configuration prohibits on-site opening of the cover for gas replenishment;

Challenge 4: Cumbersome commissioning of integrated protection systems; poor compatibility between different protection devices → Solution: Directly implement the PowerLogic P3 P5 Switchgear protection configuration, which features proven setting templates to significantly reduce on-site commissioning rework;

Pain Point 5: Risk of internal arcing and safety hazards during front-panel operation → Solution: Directional pressure relief structure with an AFL (R) 1s arc flash rating, ensuring pressure is not released toward the operating panel.

Technical Specifications of SeT Series MV Switchgear

Item Specification
Product Name Schneider GMA MV Switchgear / Schneider GMA GIS Switchgear
Product Series SeT Series MV Switchgear
Rated Voltage 12kV / 24kV
Rated Current Up to 1250A, optional 2500A export version
Rated Short-circuit Breaking Current 25kA / 31.5kA
Short-time Withstand Current 25kA / 31.5kA @ 4s
Peak Withstand Current 63kA / 80kA
Internal Arc Classification IAC AFL(R), 1s
Circuit Breaker Type Vacuum circuit breaker
Gas Tank Structure Sealed for Life, no on-site gas filling
Compatible Protection Scheme PowerLogic P3 P5 Switchgear protection configuration
Enclosure Protection (Gas Tank) IP65
Cooling Natural air cooling

Request drawings, protection schematics and project quotation for this SeT Series MV Switchgear now, our electrical engineers will reply promptly.

Application Scenarios of Schneider GMA GIS Switchgear

  • Medium-voltage distribution at grid-connection points for energy storage power stations: Schneider GMA MV Switchgear features a compact design that fits into the confined spaces of prefabricated containers and can be integrated with PowerLogic P3 P5 Switchgear protection logic
  • Above-ground main substations and open-pit mine power distribution systems: Schneider GMA GIS Switchgear is resistant to dust and condensation, making it suitable for harsh mining environments
  • Compact distribution rooms in water treatment and chemical plants: SeT Series MV Switchgear requires minimal maintenance and is suitable for unmanned sites
  • Small-scale primary substations and prefabricated substations for overseas EPC projects
  • Small distribution bays in photovoltaic and wind power collection stations

Why Buy from Funator

Funator is familiar with the overseas project acceptance standards and key supervision checkpoints for the complete set of Schneider GMA MV Switchgear cabinets, helping you proactively avoid on-site risks related to cabinet assembly and interconnection, altitude-based selection, and protection configuration.We offer a turnkey delivery solution: supply of SeT Series MV Switchgear cabinets + pre-set PowerLogic P3 and P5 Switchgear protection systems, with protection logic, CT polarity, and arc flash parameter commissioning completed in-house to reduce on-site commissioning time.Prior to shipment, we conduct mechanical interlock cycle testing, random contact resistance inspections, and air pressure signal calibration; we simultaneously provide English test reports, nameplate documentation, and operation and maintenance guidelines to meet the requirements of overseas owners and supervisors in the Gulf and North Africa; we also support staggered shipments, spare parts provision, and remote technical support.

Schneider GMA GIS Switchgear installed in indoor substation, SeT Series MV Switchgear for compact distribution projects

Schneider GMA GIS Switchgear installed in indoor substation, SeT Series MV Switchgear for compact distribution projects

FAQ: Schneider GMA MV Switchgear and PowerLogic P3 P5 Switchgear

Q1:Can the gas tank of Schneider GMA GIS Switchgear be refilled on site?

A:Standard Schneider GMA MV Switchgear adopts sealed welded gas tank for SeT Series MV Switchgear, on-site opening and gas refilling are prohibited. Opening the tank will void the factory warranty. If low gas pressure alarm triggers, check sensor wiring and secondary circuit first. This is one of the most frequent on-site mistakes.

Q2:What common issues occur when deploying the PowerLogic P3 P5 Switchgear protection scheme on GMA?

A:The cable compartment is narrow. Improper installation of arc light fiber probes will cause slow response. Wrong suppression logic setting may lead to fail-trip or false trip during secondary injection test, which often fails client inspection.

Q3:Can we force the bus plug-in contact during cabinet extension for Schneider GMA GIS Switchgear?

A:Not allowed. Misaligned contacts will cause overheating from high contact resistance. Never short the position feedback signal to energize the cabinet, overseas EPC inspectors will reject the whole panel.

Q4:Can we directly use standard parameters for high-altitude projects of SeT Series MV Switchgear?

A:When altitude>2000m, external insulation and alarm threshold must be revised. Using standard flatland parameters will usually cause withstand voltage test failure.

Q5:Is it acceptable to grind interlock parts when the 5-prevention interlock of Schneider GMA MV Switchgear gets stuck?

A:Forbidden. Grinding changes interlock travel, and may lead to closing earthing switch while circuit breaker is closed, a fatal safety hazard.

Q6:Cable terminal selection for Schneider GMA GIS Switchgear is same as KYN28 AIS cabinet?

A:Different. Cable compartment inner space margin is limited. Terminals sized for normal AIS cabinet may be squeezed and damage insulation when closing the door. Confirm terminal outer diameter before order.

Key Features

  • Compact Size — Schneider GMA MV Switchgear, saves up to 40% substation space
  • Fully Sealed Structure — Schneider GMA GIS Switchgear,dust & moisture resistant
  • Modular Expansion — SeT Series MV Switchgear, quick on-site cabinet extension
  • Flexible Protection — Works seamlessly with PowerLogic P3 P5 Switchgear

Documentation

Catalogs, CAD drawings and manuals are free — leave your work email and we send the package within 12 hours.

Application Scenarios

Where GMA delivers — typical on-site installations across industries and regions.

Schneider GMA GIS Switchgear installed in indoor industrial substation, compatible with PowerLogic P3 P5 Switchgear protection scheme

01

Schneider GMA GIS Switchgear installed in indoor industrial substation, compatible with PowerLogic P3 P5 Switchgear protection scheme

Schneider GMA GIS Switchgear installed in indoor substation, SeT Series MV Switchgear for grid distribution

02

Schneider GMA GIS Switchgear installed in indoor substation, SeT Series MV Switchgear for grid distribution

Schneider GMA MV Switchgear assembled in workshop, modular bus plug-in connection

03

Schneider GMA MV Switchgear assembled in workshop, modular bus plug-in connection