01
Low Voltage Switchgear
Schneider Blokset Ms LV switchgear for Altivar VFDs & ATS soft starters. 600mm width, Form 4 segregation & dedicated cooling for pumps, fans & water treatment.
In Stock Blokset Ms is a customized functional cabinet developed specifically for speed regulating power electronic equipment such as frequency converters and soft starters under the Schneider Blokset low-voltage complete system. It fully reuses the modular hardware framework of Blokset's universal cabinet, and provides directional structural reinforcement for the three major pain points of heat concentration, harmonic distortion, and electromagnetic interference exceeding the standard that are unique to variable frequency loads. It is a standardized delivery solution that has been verified through engineering in industrial low-voltage motor speed regulation scenarios.
The cabinet body is made of aluminum zinc coated sheet metal and formed by CNC bending. It is physically isolated into four completely independent functional compartments: busbar room, power component room, cable inlet and outlet room, and accessory installation room through metal partitions. The protection partition level reaches Form 4b and fully meets the mainstream low-voltage complete equipment standards at home and abroad, such as IEC 61439-1/2 and GB 7251.1; Its internal arc withstand peak can reach 100kA/0.5s, fully covering the safety protection requirements for short-circuit arc in heavy industry scenarios.

In response to the high heat flux density heat dissipation requirements of variable frequency components, the Ms cabinet comes standard with a top forced exhaust duct and a bottom natural air inlet with a bottom inlet and outlet convection structure. It is equipped with a customized heat dissipation installation backplate, which can efficiently take away the operating loss heat of large heat sources such as frequency converters and series reactors, avoiding local overheating triggering component overheating protection; At the same time, the cabinet has reserved a fixed installation position for the shielding layer and an independent EMC wiring channel in advance, cutting off the coupling path of the variable frequency harmonics to the surrounding control circuit from the structural level, greatly reducing the risk of signal misoperation caused by electromagnetic interference. The entire series of cabinets are manufactured under Schneider's official authorized production system. All core components are 100% made of original materials, and the installation holes, electrical clearances, and creepage distances are strictly aligned with Schneider's original design specifications. It can achieve zero tolerance seamless integration with other standard cabinet types in the Blokset series without the need for additional adjustment of busbar docking dimensions.
In response to the concentrated heating characteristics of frequency converters and reactors, a "bottom in, top out" directional ventilation structure is adopted, combined with cabinet top fans and filters, to form a stable heat dissipation duct; Compared to ordinary distribution cabinets, the average temperature inside the cabinet can be reduced by 8-12 ℃, and the operating life of components can be increased by more than 30%. It is suitable for long-term full load operation at an ambient temperature of 40 ℃.
A four room independent metal isolation structure, completely separating the busbar room, component room, and cable room, so that a single circuit fault will not affect adjacent circuits and the main busbar; The cabinet door is equipped with an interlocking mechanism as standard, which prevents the opening of the component room door when it is live. At the same time, an internal arc protection scheme can be optionally selected, and the faulty arc is discharged directionally through the top pressure release channel to ensure the safety of operation and maintenance personnel.
Perfectly compatible with Schneider's full range of ATV frequency converters (ATV310/ATV610/ATV930, etc.), ATS soft starters (ATS22/ATS48, etc.), supporting a complete circuit configuration of incoming circuit breakers+reactors+frequency converters/soft starters+outgoing terminals; Peripheral components such as input reactors, output reactors, EMC filters, and braking units can be selected according to working conditions. All installation positions are standardized and reserved, without the need for on-site drilling and modification.
The components adopt a front installation and front maintenance structure, and all wiring, debugging, and replacement operations can be completed in front of the cabinet; The cabinet frame is designed with standard modular design. When upgrading component power or adding accessories in the future, it can be directly modified on the original cabinet without replacing the entire cabinet, reducing expansion costs.
| Parameter | Unit | Value |
|---|---|---|
| Rated Insulation Voltage | V | 1000 |
| Rated Operating Voltage | V | 380 / 400 / 690 |
| Rated Frequency | Hz | 50 / 60 |
| Main Busbar Rated Current | A | ≤6300 |
| Rated Short-Time Withstand Current (1 s) | kA | 50 / 80 / 100 |
| Rated Peak Withstand Current | kA | 105 / 176 / 220 |
| Internal Separation Form | - | Form 4b |
| Internal Arc Withstand Rating | kA/s | ≤100 / 0.5 |
| Standard Panel Width | mm | 600 |
| Panel Height | mm | 2200 |
| Panel Depth | mm | 600 / 1000 |
| Enclosure Protection Degree | - | IP30 / IP40 (IP54 optional) |
| Applicable Standards | - | IEC 61439-1/2, GB 7251.1 |
| Operating Ambient Temperature | ℃ | -5 ~ +40 |
| Altitude for Standard Rating | m | ≤2000 (derating required above this value) |
⚠️ Kind Reminder:
For high-altitude projects with an altitude exceeding 2000m, the air is thin and the heat dissipation capacity decreases. If the selection is directly based on plain parameters, the frequency converter will experience overheating, reduced capacity, frequent protection, and in severe cases, the module may be directly burned. We have dealt with such issues in a photovoltaic project in Qinghai, but the customer did not inform us of the altitude in the early stage. After arrival, all high-power components need to be replaced and heat dissipation solutions need to be strengthened.
Avoidance method: Before selecting, confirm the altitude of the site. For elevations above 2000m, calculate a 5% -8% reduction in capacity for every 1000m increase. Simultaneously upgrade the cooling fan and air duct structure.
Schneider Blokset Ms frequency conversion special cabinet is a low-voltage complete set solution customized and developed for speed control power electronic equipment such as frequency converters and soft starters. It relies on the modular framework of Blokset universal cabinet to achieve targeted optimization of frequency conversion scenarios, and can be widely adapted to the four core areas of industry, infrastructure, water treatment, and HVAC. In the water treatment industry, it can achieve constant pressure water supply and precise flow control through frequency conversion speed regulation, saving 20% -40% energy compared to traditional valve throttling. The exclusive heat dissipation structure can adapt to high tide, humid, and dusty environments in pump rooms to ensure long-term stable operation; In the HVAC scenario, the central air conditioning freezing pumps, cooling pumps, and cooling tower fans in commercial buildings and industrial parks can automatically adjust their speed according to load changes, significantly reducing the energy consumption of the air conditioning system. The low interference design completely avoids the impact on the building's self-control system and meets the EMC requirements of commercial power distribution; In industrial production lines such as metallurgy, mining, building materials, and food processing, equipment such as belt conveyors, elevators, and mixers can be equipped with soft start solutions to significantly reduce starting impact and extend equipment mechanical life. Variable frequency speed regulation can achieve precise speed control, perfectly matching the process requirements of various production lines; At the same time, this solution is also suitable for auxiliary systems of photovoltaic and energy storage power stations, as well as public infrastructure scenarios such as municipal pumping stations and rail transit ventilation systems. The fully standardized modular structure supports rapid consolidation to form a complete set of MCC systems, fully meeting the rigid requirements of short-term project delivery.

⚠️ On site pit reminder:
In flammable and explosive scenarios such as coal mines and chemical industries, if ordinary cabinet types are used without explosion-proof adaptation, there may be safety hazards and they cannot pass safety supervision and acceptance.
Avoidance method: For special explosion-proof and anti-corrosion scenarios, customized explosion-proof and anti-corrosion cabinet solutions can be provided. All components should be selected from corresponding explosion-proof grade products, and complete compliance qualifications should be issued.
As an officially certified Blokset authorized complete set partner of Schneider, we have established a complete closed-loop guarantee system from material source, preliminary selection, factory verification to full cycle on-site service, fully meeting the strict delivery requirements of industrial power distribution projects: all Blokset Ms frequency conversion cabinets are 100% strictly aligned with Schneider's original design specifications for production and manufacturing, and the core frequency conversion transmission components and main circuit breakers are all made of Schneider's original materials. The serial numbers of each component can be traced and verified through Schneider's official channels, completely preventing non-standard cabinets with counterfeit parts, refurbished parts, and unauthorized reductions from entering the project site from the root.
Our core technology team has over 10 years of experience in implementing low-voltage distribution and transmission systems. Before placing an order for a project, they complete a comprehensive pre check, including accurate calculation of motor rated parameters, simulation analysis of system harmonic content, thermal efficiency verification of cabinet heat dissipation capacity, confirmation of on-site installation environment boundary conditions, and ultimately output a complete customized selection confirmation form to avoid high-frequency stepping problems such as power mismatch, insufficient heat dissipation margin, and harmonic exceeding triggering protection at the source.
After each cabinet is taken offline, a complete set of factory routine tests must be completed, including power frequency withstand voltage insulation test, main circuit contact resistance test, complete machine power on no-load test run, full logic verification of mechanical and electrical interlocking function, and point by point verification of secondary circuit on and off. A complete factory test report, product certificate, and Schneider official complete set of authorization documents are attached with the goods. Customers are allowed to come to the site for on-site inspection throughout the process, and third-party authoritative testing institutions are also supported to complete independent acceptance on-site.
Full efficiency of business and technical response throughout the entire chain: complete all technical consultation and inquiry needs within 24 hours, and output formal quotations within 48 hours for standard solutions; The delivery cycle of standard cabinet configuration is stably controlled within 20-30 days, and the entire logistics chain can be tracked in real time; After project delivery, we provide full cycle localized technical support, covering the entire process of on-site installation disclosure guidance, power on and load debugging, and operation parameter optimization settings. During the warranty period, we achieve rapid response to fault demands without the need for cross regional coordination resources from the project party.
The Ms type is a specialized cabinet designed for frequency converters and soft starters, with added directional heat dissipation ducts, EMC shielding structures, and dedicated component installation positions to ensure long-term stable operation of speed control components; D-type is a universal distribution cabinet that is only suitable for distribution components such as circuit breakers and isolating switches. It cannot be directly used in frequency conversion circuits, otherwise problems such as insufficient heat dissipation and excessive interference may occur.
The standard solution is compatible with Schneider's full range of frequency converters/soft starter components; If you need to adapt to other brands, you can provide component dimensions and installation drawings. We will conduct hole opening and heat dissipation verification according to the specifications to ensure compliance with installation and operation, but we do not enjoy Schneider's overall warranty.
600mm wide and 1000mm deep cabinet, with a maximum capacity of 315kW low-voltage frequency converter per unit; It is recommended to adopt a parallel cabinet scheme for power of 400kW and above, and set up a separate reactor cabinet to ensure heat dissipation and wiring space.
The standard cabinet is an indoor type with a maximum protection level of IP54; Outdoor use requires the installation of an outdoor rain cover or placement in a transformer or prefabricated cabin, and cannot be directly installed outdoors.
Support, all cabinet types of Ms cabinet and Blokset series, including D-type, Mx type, Mw type, etc., have the same size and can be seamlessly combined to form a complete low-voltage system including incoming lines, distribution, frequency conversion, and soft start.
Not mandatory, but strongly recommended to configure. The incoming reactor can suppress the impact of the power grid, reduce harmonic currents, improve the service life of the frequency converter, and avoid harmonic pollution of the power grid; For scenarios with large power grid capacity and high requirements for harmonics, it is necessary to configure.
Catalogs, CAD drawings and manuals are free — leave your work email and we send the package within 12 hours.
Where Blokset Ms delivers — typical on-site installations across industries and regions.
01
02
03
Inquiry