01
Low Voltage Switchgear
Type-tested LV switchboard for power distribution up to 6300 A — the standard choice for industrial plants, infrastructure and large buildings.
In Stock Schneider Electric BlokSeT D is a fixed-type low voltage switchgear designed for main power distribution, feeder protection and busbar control in industrial and commercial facilities. Installed downstream of transformers, it distributes incoming power through main and distribution busbars to outgoing circuits.
The system supports Schneider Masterpact air circuit breakers, molded case circuit breakers and other protection devices according to project requirements. Its compartmentalized design provides organized spaces for busbars, electrical components, cables and auxiliary wiring.
The BlokSeT range supports operating voltages up to 690 V AC, insulation voltage up to 1,000 V and impulse withstand voltage up to 12 kV. Current ratings and short-circuit capabilities depend on the selected configuration.
BlokSeT D is suitable for industrial distribution, transformer substations and commercial power systems. Final selection should follow the project single-line diagram and technical specifications.

1. High-Capacity Main Power Distribution
- Horizontal main busbar capacity up to 7,000 A in the referenced BlokSeT design.
- Incoming and outgoing circuit-breaker arrangements up to 6,300 A, subject to configuration.
- Designed for high-current transformer-fed distribution systems.
2. Flexible Circuit Breaker Installation
- Supports Schneider Masterpact circuit breakers.
- Fixed or withdrawable breaker arrangements are available.
- Other switching devices can be installed according to the functional design.
3. Compartmentalized Internal Structure
- Separate busbar, component, cable and auxiliary compartments.
- Defined wiring and mounting areas simplify installation and inspection.
- Internal separation can be selected according to project safety and maintenance requirements.
4. Flexible Cable Connection
- Top or bottom cable entry options.
- Front or rear connection arrangements.
- Different cabinet widths and depths to suit electrical room layouts.
5. Multiple Protection and Separation Options
- IP20, IP31, IP42 and IP54 options according to the Schneider D-type reference.
- Internal separation forms include Form 1, Form 2b, Form 3b and Form 4.
- Final IP rating and separation must be verified for the selected assembly.
6. Verified Electrical Performance
- Electrical design verification includes temperature-rise, dielectric and short-circuit withstand assessments.
- Mechanical operation and protective circuit effectiveness are also subject to verification.
- Applicable type-test evidence should be requested for the offered configuration.
| General Data | |
|---|---|
| Applications | Power Distribution, Motor Control |
| Reference Standard | GB/T 7251.1 / 7251.12 |
| Installation Location | Indoor |
| Ambient Temperature | -5°C to +40°C |
| Relative Humidity (at 40°C) | ≤ 50% |
| Maximum Installation Altitude | ≤ 2000 m |
| Electrical Parameters | |
| Rated Operating Voltage (Ue) | 400 VAC |
| Rated Insulation Voltage (Ui) | 1000 VAC |
| Rated Impulse Withstand Voltage (Uimp) | 12 kV |
| Overvoltage Category | IV |
| Pollution Degree | 3 |
| Rated Frequency | 50 / 60 Hz |
| Horizontal Busbar Rated Current | 5000 A |
| Horizontal Busbar Rated Short-Time Withstand Current | 42 / 50 / 65 / 85 / 100 kA / 1 s |
| Horizontal Busbar Rated Peak Withstand Current | 88 / 105 / 143 / 187 / 220 kA |
| Vertical Busbar Rated Current | 2350 A |
| Vertical Busbar Rated Short-Time Withstand Current | 30 / 50 / 65 kA / 1 s |
| Vertical Busbar Rated Peak Withstand Current | 63 / 105 / 143 kA |
| Earthing System | TT / IT / TN-S / TN-C |
| Maximum Incoming / Outgoing Switch Rating | 5000 A |
| Maximum Motor Capacity | 160 kW |
| Reactive Power Compensation – Natural Ventilation | 200 kVAr |
| Reactive Power Compensation – Forced Ventilation | 400 kVAr |
| Mechanical Parameters | |
| Overall Height | 2200 mm |
| Effective Height | 2000 mm |
| Cabinet Width | 600 / 800 / 1000 / 1200 / 1600 mm |
| Cabinet Depth | 1000 mm |
| Internal Separation Form | Form 2b / Form 3b |
| Protection Degree | IP30 / IP31 / IP40 / IP41 |
| Cabinet Surface Treatment | Epoxy Resin Powder Electrostatic Coating |
| Standard Cabinet Color | RAL 9003 |
Note:Specifications and dimensions are based on the provided product information. Actual values may vary depending on voltage rating, panel configuration, current rating and installation requirements. Please confirm the final dimensions and technical ratings against the approved drawings, and contact us for further technical assistance or product inquiries.
Main Panel Configurations
1. Main Incomer Panel
- Receives incoming power from transformers or generators.
- Supports high-capacity Masterpact circuit breakers.
2. Outgoing Feeder Panel
- Distributes power to downstream distribution boards and industrial loads.
- Supports selected fixed, plug-in or withdrawable breaker arrangements.
3. Busbar Section Panel
- Divides the main busbar into separate sections.
- Supports sectionalized distribution and operational flexibility.
4. Bus Coupler Panel
- Connects two busbar sections through a coupling circuit breaker.
- Used in systems requiring alternative power supply arrangements.
5. Dual Power Supply Panel
- Supports transfer between two incoming power sources.
- Requires a coordinated electrical and mechanical interlocking scheme.
Optional Components and Accessories
- Schneider Masterpact NT / NW / MTZ air circuit breakers, subject to compatibility and selection.
- Schneider ComPacT NS / NSX molded case circuit breakers.
- Current transformers and voltage transformers.
- Multifunction power meters and protection relays.
- Automatic transfer switches.
- Surge protection devices.
- Busbar monitoring and temperature sensors.
- Auxiliary control circuits and communication interfaces.
Mechanical and Installation Options
- Fixed or withdrawable Masterpact installation.
- Fixed, plug-in or withdrawable vertical breaker arrangements where supported.
- Top or bottom cable entry.
- Front or rear cable connection.
- IP20, IP31, IP42 or IP54 protection options.
- Internal separation according to the selected Form requirement.
1. Schneider BlokSeT D for Industrial Main Power Distribution
Used as the main low-voltage distribution switchboard in manufacturing plants. It receives transformer power and distributes electricity to production lines, machinery and auxiliary systems.
2. Schneider BlokSeT D for Transformer Distribution Substations
Installed on the low-voltage side of distribution transformers to provide main circuit protection, feeder distribution and busbar sectionalizing.
3. Schneider BlokSeT D for Data Center Electrical Systems
Suitable for main low-voltage distribution and downstream feeder protection in data center electrical rooms. Incomer, bus coupler and outgoing feeder configurations can be coordinated with the facility's redundancy design.
4. Schneider BlokSeT D for Oil and Gas Facilities
Used for low-voltage power distribution to pumps, compressors, auxiliary systems and industrial equipment. Enclosure protection and corrosion requirements must be checked against the actual site environment.
5. Schneider BlokSeT D for Water Treatment and Desalination Plants
Provides incoming power distribution and feeder protection for water pumps, treatment equipment and auxiliary electrical loads.
6. Schneider BlokSeT D for Commercial and Infrastructure Projects
Suitable for main electrical distribution in airports, commercial buildings, hospitals, transportation facilities and large public infrastructure projects.

Funator provides project-based sourcing, technical coordination and export support for Schneider Electric low-voltage distribution equipment.
1. Brand and Supply Verification
We confirm the offered product range, manufacturing entity, applicable Schneider Electric authorization and component brand before order confirmation.
2. Technical Model Matching
Our team reviews the single-line diagram, rated current, busbar capacity, short-circuit level, Masterpact breaker selection, protection degree and internal separation requirements to avoid configuration mismatches.
3. Project-Based Pricing
We prepare quotations based on the actual panel schedule and bill of materials. Where required, pricing can be itemized by cabinet sections, circuit breakers, accessories, testing and logistics.
4. Production Lead-Time Coordination
We check component availability, manufacturing capacity and drawing approval status before confirming the delivery schedule. Production updates can be provided during order execution.
5. Pre-Shipment Inspection
Before dispatch, we can coordinate inspection of cabinet appearance, nameplates, quantities, circuit-breaker models, internal wiring, accessories and packing condition. Photo and video records can be provided.
6. Factory Acceptance and Testing
We coordinate applicable factory routine verification and project FAT requirements, including mechanical operation, electrical connections, protective circuit checks and dielectric tests as specified.
7. Test Reports and Technical Documents
We help collect available technical datasheets, approved drawings, bills of materials, routine verification records, applicable type-test evidence and manufacturer documents.
8. International Logistics
We coordinate export packing, shipping arrangements and delivery documentation. Sea freight, air freight and suitable door-to-door delivery options can be discussed according to the destination.

1. What is the price of Schneider BlokSeT D?
Pricing depends on rated current, busbar configuration, circuit breakers and panel quantity. Send us your specifications for a quotation.
2. What is the delivery time for BlokSeT D?
Lead time depends on configuration and component availability. We confirm the production schedule after order and drawing approval.
3. Is Schneider BlokSeT D available from stock?
Stock availability depends on the selected configuration. Customized switchgear is supplied according to the approved project requirements.
4. Can you provide technical drawings and test reports?
Yes. Available documents include datasheets, GA drawings, wiring diagrams, BOMs and applicable factory test reports.
5. Can I inspect the switchgear before shipment?
Yes. Pre-shipment inspection and factory acceptance testing (FAT) can be arranged according to the agreed inspection requirements.
6. What warranty is provided for BlokSeT D?
Warranty coverage follows the manufacturer's policy and the sales contract. After-sales technical support and spare parts enquiries can also be coordinated.
7. Do you arrange international shipping?
Yes. We can arrange export packing and sea or air freight, with FOB, CIF and DDP options subject to destination.
8. Can BlokSeT D be customized to match my project?
Yes. Busbar ratings, Masterpact breakers, protection devices, IP ratings and internal separation can be selected according to your single-line diagram.
Catalogs, CAD drawings and manuals are free — leave your work email and we send the package within 12 hours.
Where BlokSeT D delivers — typical on-site installations across industries and regions.
01
02
03